NBE V7 User Manual Download Page 1

NBE PELLETS SYSTEM  

V

7 & 

V

10 

EN303-5 2012 Class 5 

approved by DTI. 

Approved for expansion vessel. 

Energy class AA. 

 

 

 

Manufacturer: 

NBE Production A/S 

Brinken 6-10 Øster Vrå  

Denmark 

www.nbe.dk

 

 

Summary of Contents for V7

Page 1: ...NBE PELLETS SYSTEM V7 V10 EN303 5 2012 Class 5 approved by DTI Approved for expansion vessel Energy class AA Manufacturer NBE Production A S Brinken 6 10 ster Vr Denmark www nbe dk...

Page 2: ...scribed here in this manual It is recommended to study the menus prior to initial start Save this manual so you always have it available when needed Page 3 Comments on the Manual Page 4 Boiler Specifi...

Page 3: ...indication of improper draft of the chimney all operation of your system must cease immediately and must remain so until a solution to the draft problem has been resolved Continuing operation may res...

Page 4: ...ing Efficiency 93 3 93 4 94 7 91 4 EN Class 5 5 5 5 Output 10kW 14kW 24 kW 48kW 300 ELAB 1683 1700 1765 1859 Black Star BS20 BS30 BS30 BS40 Height mm 980 980 980 1084 Width mm 430 530 530 628 Depth mm...

Page 5: ...4kW burner Up to 110kg day 60 watt hour Weight 12kg 30kW burner Up to 150kg day 80 watt hour Weight 15kg 40 60kW burner Up to 300kg day 150 watt hour Weight 30kg 80 120kW burner Up to 600kg day 200 wa...

Page 6: ...stance to prevent temperatures from reaching an excess of 80 C This requirement applies even if the combustible material is covered with non flammable material If the distance is greater than 500 mm t...

Page 7: ...oke in the hopper Warm drop shaft Smoke billows out of the fan or boiler during startup If you have any problems with your chimney it is a good idea to keep a diary of any draft problem as draft probl...

Page 8: ...xcept oil for oil burners The floor must be kept free of spilled fuel dust and combustible waste as well as waste from other activities in the room Any burning embers must be extinguished with water a...

Page 9: ...degrees Buildings with a roof slope that is less than 20 degrees and is adjacent to another building Buildings with a slope greater than 20 degrees Buildings with a slope greater than 20 degrees and h...

Page 10: ...mall Heat for the house is supplied while hot water is being produced 3 DHW with 3 way valve Typically used when the water heater is large and when the surface coil is large The house is not supplied...

Page 11: ...r must not be installed on combustible surfaces 3 Un insulated smoke pipe must not exceed 0 30 m long and must be provided with an access door 4 Chimney draft should be a min 5 PA and be stable Overpr...

Page 12: ...tor on the burner 6 Install electricity for safety cut off thermostat according to the wiring diagram SAFETY THERMOSAT MUST ALWAYS BE FUNCTION TESTED The thermostat can be tested by using an electric...

Page 13: ...tween C and C2 is interrupted and that the high limit safety thermostat is triggered To re activate the thermostat press hard on the red button marked B in the drawing You will also hear a click signa...

Page 14: ...l Hopper Available in 4 different models 60x60cm 200L 140 kg 80x80cm 320L 220kg 80x140cm ext 500L 350kg 100x100cm 500L 350kg Fabric hopper Available in 3 different models with gate over the auger inle...

Page 15: ...our vacuum transport Big bag Throw the mole in the bag Easy way to transport 1 ton Flat bottom hopper Is a top fed option that maximizes space by minimizing ceiling height requirements V bottom hopper...

Page 16: ...may be factory installed wiring on the outputs L5 L10 L5 may be factory fitted for the moving grate L6 may be factory fitted for the compressor cleaning Remove these if there is a need for other equi...

Page 17: ...output for equipment EKSTRA 3 PE N L9 Optional output for equipment EKSTRA 3 PE N L10 Optional output for equipment BUS GRD TX RX Expansion module ILT V1 V V2 O2 controller KONTAKT K K1 External ON O...

Page 18: ...Cleaning L Cleans the burner head efficiently with high pressure Low noise compressor included Solar Heating Use the pellet burner controller to run your solar system External Temp Sensor Stops burne...

Page 19: ...that the controller is online If you do not have the possibility of a direct cable connection these adapters picture on right can be used They can establish a connection to your router through your h...

Page 20: ...will now have your own page with your own burner dashboard After a short period of time you should see data streaming from the burner Do you want data on your mobile phone Then download our App for t...

Page 21: ...your graphs You will be contacted by E mail where we ask your permission to make changes NBE will assess your graphs and the burner reaction pattern and make adjustments based on the observations You...

Page 22: ...le flame at 10 power 6 Once the burner is activated an ignition will be made After approx 20 minutes the burner will reach a nominal output 100 If necessary lock the burner output at 100 Now you can p...

Page 23: ...surfaces inside the boiler must be brushed clean from any deposits and the ash can must be emptied When empting the ash can pay special attention to any build up of ash in the rear smoke chamber and f...

Page 24: ...01 04 12 Kg 87 Empty ash container 1000 ON NEJ 01 12 13 19 Cleaning of semi cleaning 2000 ON NEJ 31 12 12 25 Cleaning under burning grate 1000 ON NEJ 31 12 12 50 Cleaning of fan 5000 ON NEJ 31 12 12 0...

Page 25: ...grate is fitted wrong Mount it correctly Too high chimney draft Install a draft stabilizer in the chimney Set electric ignition power up Reduce the fan speed during ignition Stopped fan Check if the f...

Page 26: ...ate with pipe insulation Too many electric ignitions Flow in the system is fluctuating Set the pressure controlled circulation pump to fixed pressure External thermostat unstable Set External wait up...

Page 27: ...ir flow in the boiler and carries more moisture 1 more oxygen costs approx 0 5 in efficiency 10 Remove the retarder Turbolator Decreases resistance of the boiler and get a bad chimney to work better T...

Page 28: ...de by agreement with NBE To the extent that NBE is liable to the purchaser NBE s liability is limited only to direct loss and not to damages incurred by connected equipment and or indirect damage loss...

Page 29: ...CE Declaration of Conformity...

Reviews: