background image

3

PARTS LIST

ITEM 

NO.

PART 

NO.

DESCRIPTION

Size (inch)

IMAGE

QTY.

1

S1

Full Frame

78.74 x 40.74

5

2

CB1

Corner Bracket - CB1

4.3 x 4.3 x 1.57

8

3

JF1

Joint Flat - JF1

4.33 x 1.57

7

4

P1

Post Frame - P1

78.74 x 40.74

2

5

ST5

ST5 Roof Tie Bar

60.75

2

6

P5

P5 POST

77.15 x 1.57 x 

1.57

1

7

JFT

Bracket

8.66 x 5.9

1

8

DR

Rafter Bracket

4.3 x 1.6 x 2

12

9

DR2R

DR2R Rafter

92.32

4

10

DR2I

DR2 infill panel

85 x 15.75

2

11

DR2PO

DR2 Roof Panel Outer

92.32 x 41.54

2

12

DR2PI

DR2 Roof Panel Inner

40.75 x 92.30

1

13

DR2T

DR2 Roof Trim

92.32 x 3.15

4

14

DRATO

DR Ally-Angle Trim Outer

2 x 2 x 41.5 

4

15

DRATI

DR Ally-Angle Trim Inner

2 x 2 x 40.75

2

16

FT1

FT1 BRACKET

1.57 x 1.57 x 

3.94

5

17

FT3

FT3 Bracket

1.57 x 3.15 x 

4.17

4

18

EC40

Plastic end cap

1.6 x 1.6

6

Summary of Contents for SR8299

Page 1: ...Assembly Instructions Shelter Type SR8299 SR8299 01 28102021 USA...

Page 2: ...14 15 10 14 10 11 1 4 4 11 9 5 5 9 2 8 16 17 6 7 3 15 12 14 14 2 EXPLODED VIEW...

Page 3: ...7 JFT Bracket 8 66 x 5 9 1 8 DR Rafter Bracket 4 3 x 1 6 x 2 12 9 DR2R DR2R Rafter 92 32 4 10 DR2I DR2 infill panel 85 x 15 75 2 11 DR2PO DR2 Roof Panel Outer 92 32 x 41 54 2 12 DR2PI DR2 Roof Panel I...

Page 4: ...ed Drill Screwdriver Mallet 17mm Wrench T25 Torx bit Fittings Bolt set M10 T25 T38 BTANCM12100 M10 x 60mm Nut Washer 1 Tech screw 1 5 Tech screw Black Caps M10 12 x 100 mm Concrete Bolt Pack A B 33 33...

Page 5: ...1 JFT ST5 P5 ENSURE CORRECT ALIGNMENT ON CORNERS JF1 CB1 CB1 CB1 JF1 JF1 JF1 JF1 JFT DETAIL A SCALE 1 10 DETAIL B SCALE 1 10 DETAIL C SCALE 1 10 DETAIL D SCALE 1 10 Step 1 Assemble S1 frames to make u...

Page 6: ...DR2R DR2R DR2R 40 75 40 75 40 75 RAFTER PLACEMENT 6 Step 2 Attach DR2R rafters using DR brackets Secure the END PANELS DR2I to frames using tec screws The end rafters need to be placed in position at...

Page 7: ...DR2PI 7 Step 3 Attach the DR2PO and DR2PI Panels to the top of the rafters with the DR2PO on either end and the DR2PI in between Seal the gap between the panels using the DR2T strips Attach the DRATO...

Page 8: ...FT1 x5 FT3 x4 8 Step 4 Move the shelter into its desired position and attach the foot brackets FT1 FT3 before fixng in place...

Page 9: ...40 75 81 87 39 17 41 12 38 27 77 44 PLAN VIEW OVERALL DIMENSIONS AND GROUND FIXING POSITIONS Suggested size for concrete base 8 oversized on all 4 sides 9...

Page 10: ...anels regularly with soapy water Ensure all fittings are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS Email Sales nobutts com Web www nobutts...

Reviews: