PARTS LIST

ITEM 

NO.

PART NUMBER

DRG number

Size (inch)

IMAGE

QTY.

1

S1C Frame

SC1

78.74 x 40.74

9

2

Post P1

P1

78.75 x 40.5

1

3

JF1 Bracket

JF1

4.33 x 1.57

12

4

FT1 BRACKET

FT1

1.57 x 1.57 x 3.94

3

5

DR Bracket

DR 

4.3 x 1.6 x 2

16

6

AR2R  2m Pitch Rafter

AR2R

85.75

5

7

AR2POA  AR2 Roof 

Panel outer ALU

AR2POA

45.5 x 41.3

4

8

AR2IS  2m Pitch Infill 

Panel Shallow

AR2IS

85

2

9

AR2TS  2m Apex Roof 

Trim strip

AR2TS

45.5 x 2.3

6

10

FT3 Bracket

FT3

1.57 x 3.15 x 4.17

8

11 CB1 Bracket

CB1

4.3 x 4.3 x 1.57

9

12  Roof centre lower 

trim outer

AR2CLTO-03

41.4

2

13  Roof centre lower 

trim inner

AR2CLTI-02

40.74

2

14 Roof F Section 

Outer

ARFSO

41.5

4

15 ARFSI  Apex Roof F 

Section Inner

ARFSI

40.75

4

16 AR2PIA  AR2 Roof 

Panel inner ALU

AR2PIA

45.5 x 40.5

4

17 Roof centre upper 

trim outer

AR2CUTO-02

41.5

2

18 Roof centre upper 

trim inner

AR2CUTI

40.75

2

19 ST3 Roof Tie

ST3

81.1

1

20 40x40 Plastic End 

Cap

EC40

1.6 x 1.6

3

Summary of Contents for SR8064-F

Page 1: ...Assembly Instructions Shelter type SR8064 F SR8064F 01 03112021 USA...

Page 2: ...7 7 17 8 14 5 11 10 10 4 4 19 2 1 14 17 9 18 16 16 9 3 5 6 6 20 20 20 2 Exploded View...

Page 3: ...low AR2IS 85 2 9 AR2TS 2m Apex Roof Trim strip AR2TS 45 5 x 2 3 6 10 FT3 Bracket FT3 1 57 x 3 15 x 4 17 8 11 CB1 Bracket CB1 4 3 x 4 3 x 1 57 9 12 Roof centre lower trim outer AR2CLTO 03 41 4 2 13 Roo...

Page 4: ...4 FIXINGS...

Page 5: ...RRECT ALIGNMENT Please note 1 5 Tech Screws are for roof panels only S3C CB1 JF1 Ensure correct alignment on all corners CB1 JF1 Step 1 Assemble S1C frames to make up the main structure using CB1 brac...

Page 6: ...ST3 CB1 P1 JF1 ST3 P1 Step 2 Use JF1 and CB1 brackets to attach the P1 post and ST3 Tie bar 6...

Page 7: ...R DR DR DR DR DR DR 40 75 40 75 40 75 40 75 FRONT VIEW Step 3 Attach A2R2 rafters unsing DR brackets Secure the AR2IS End Panels to the frames using Tech Screws The end rafters need to be placed in po...

Page 8: ...AR2CLTO ARFSI ARFSI AR2CLTO ARFSO ARFSO ARFSI ARFSI ARFSO ARFSO AR2CLTI ARFSI ARFSI AR2CLTI AR2CLTO Attach the AR2CLTI and AR2CLTO to the top of the rafters The ARFSI and ARFSO parts are to be attach...

Page 9: ...lign the outer roof panels AR2POA with the outer edges of the shelter and space the AR2PIA panels central Use the AR2TS strips to seal the gap between the roof panels and cap off the top with the AR2C...

Page 10: ...83 164 6 10 PLAN VIEW OVERALL DIMENSIONS AND GROUND FIXING POSITIONS Suggested size for concrete base 8 oversized on all 4 sides...

Page 11: ...anels regularly with soapy water Ensure all fittings are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS Email Sales nobutts com Web www nobutts...

Reviews: