background image

 123.8 

 83 

10

PLAN VIEW

OVERALL DIMENSIONS AND GROUND FIXING POSITIONS

Suggested size for concrete base: 8" oversized on all 4 sides.

Summary of Contents for SR8063-F

Page 1: ...Assembly Instructions Shelter type SR8063 F SR8063F 01 02112021 USA ...

Page 2: ...20 8 8 8 18 9 11 1 2 5 3 1 4 12 9 7 16 13 6 21 2 Exploded View ...

Page 3: ...fill Panel Shallow AR2IS 85 2 10 AR2TS 2m Apex Roof Trim strip AR2TS 45 5 x 2 3 4 11 FT3 Bracket FT3 4 3 x 3 9 x 3 1 7 12 ST5 Roof Tie ST5 60 75 1 13 CB1 Bracket CB1 4 3 x 4 3 x 1 6 7 14 Roof centre lower trim outer AR2CLTO 03 41 4 2 15 Roof centre lower trim inner AR2CLTI 02 40 74 1 16 Roof F Section Outer ARFSO 41 5 4 17 ARFSI Apex Roof F Section Inner ARFSI 40 75 2 18 AR2PIA AR2 Roof Panel inne...

Page 4: ...4 FIXINGS ...

Page 5: ... ALIGNMENT Please note 1 5 Tech Screws are for roof panels only S1C S3C CB1 JF1 CB1 CB1 CB1 JF1 Ensure correct alignment on all corners JF1 Step 1 Assemble S1C frames to make up the main structure using CB1 brackets for the corners and JF1 brackets for the straight joints 5 ...

Page 6: ...ST5 JF1 CB1 P1 ST5 P1 Step 2 Use JF1 and CB1 brackets to attach the P1 post and ST5 Tie bar 6 ...

Page 7: ...R AR2R AR2R 40 75 40 75 40 75 FRONT VIEW Step 3 Attach A2R2 rafters unsing DR brackets Secure the End Panels to the frames using 1 Tech Screws The end rafters need to be placed in position at the same time as the AR2IS 7 ...

Page 8: ...RFSO ARFSI ARFSO ARFSO ARFSI AR2CLTO AR2CLTO ARFSO ARFSO ARFSI ARFSI ARFSO ARFSO AR2CLTI Attach the AR2CLTI and AR2CLTO to the top of the rafters The ARFSI and ARFSO parts are to be attached to the lower part of the rafter as shown below 8 ...

Page 9: ... roof panels AR2POA with the outer edges of the shelter and space the AR2POI panels central Use the AR2TS strips to seal the gap between the roof panels and cap off the top with the AR2CUTO AR2CUTI Once the shelter is in the final position it can be secured to the ground using FT3 and FT1 brackets and the concrete bolts 9 Step 5 ...

Page 10: ...123 8 83 10 PLAN VIEW OVERALL DIMENSIONS AND GROUND FIXING POSITIONS Suggested size for concrete base 8 oversized on all 4 sides ...

Page 11: ...panels regularly with soapy water Ensure all fittings are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS Email Sales nobutts com Web www nobutts com Tel 10888 662 8887 No Butts Bin Company Inc 16 Birch lane Madison CT 06443 All Parts and Fixings checked by Print Name Signature ...