background image

3

PARTS LIST

ITEM NO.

PART NUMBER

DRG 

NUMBER 

Size (inch)

IMAGE

QTY.

1

S1C Frame

S1C

78.74 x 40.74

6

2

Post P1

P1

78.75 x 40.5

1

3

ST1 Roof Tie

ST1

40.35

1

4

CB1 Bracket - Slotted

CB1

4.3 x 4.3 x 1.57

7

5

JF1 Bracket

JF1

8.7 x 1.6

6

6

FT1 BRACKET

FT1

4.3 x 3.9 x 1.6

3

7

DR Bracket

DR 

4.3 x 1.6 x 2

8

8

AR2R  2m Pitch Rafter

AR2R

85.75

3

9

AR2CLT2  2m Apex 

Roof centre lower trim 

2m

AR2CLT2

82.85

1

10

AR2POA  AR2 Roof 

Panel outer ALU

AR2POA

45.5 x 41.3

4

11

AR2CUT2  2m Apex 

Roof centre upper 

trim 2m

AR2CUT2

83

1

12

AR2IS  2m Pitch Infill 

Panel Shallow

AR2IS

85

2

13

AR2TS  2m Apex Roof 

Trim strip

AR2TS

45.5 x 2.3

2

14

ARFS2  Apex Roof F 

section 2m

ARFS2

83.1 x 2 x 2 

2

16

FT3 Bracket

FT3

4.3 x 3.9 x 3.1

5

17

40x40 Plastic End 

Cap

EC40

1.6 x 1.6

3

Summary of Contents for SR8062-F

Page 1: ...Assembly Instructions Shelter type SR8062 F SR8062 F 01 011121 USA...

Page 2: ...11 10 13 12 8 7 1 14 16 6 4 2 5 9 3 15 17 2 Exploded Parts...

Page 3: ...acket DR 4 3 x 1 6 x 2 8 8 AR2R 2m Pitch Rafter AR2R 85 75 3 9 AR2CLT2 2m Apex Roof centre lower trim 2m AR2CLT2 82 85 1 10 AR2POA AR2 Roof Panel outer ALU AR2POA 45 5 x 41 3 4 11 AR2CUT2 2m Apex Roof...

Page 4: ...4 FIXINGS...

Page 5: ...1 5 Tec Screws are for roof panels only S1C A B C CB1 CB1 CB1 JF1 Ensure correct alignment on all corners JF1 DETAIL A SCALE 1 10 DETAIL B SCALE 1 10 DETAIL C SCALE 1 10 Step 1 Assemble S1C frames to...

Page 6: ...ST1 JF1 CB1 JF1 P1 EC40 EC40 EC40 ST1 P1 Step 2 Use JF1 and CB1 brackets to attach the P1 post and ST1 Tie bar 6 INSERT PLASTIC END CAPS EC40 INTO ST1 AND P1...

Page 7: ...40 75 ENSURE CORRECT ALIGNMENT OF RAFTERS AND S1C FRAMES Step 3 Attach A2R2 rafters using DR brackets Secure the AR2IS End Panels to S1C frames using 1 TECH Screws The end rafters need to be placed i...

Page 8: ...Step 4 ARFS2 AR2CLT2 ARFS2 Attach the AR2CLT2 to the top of the rafters The ARFS2 parts are to be attached to the lower part of the rafter as shown below 8...

Page 9: ...n the outer roof panels AR2POA with the outer edges of the shelter Use the AR2TS strips to seal the gap between the roof panels and cap off the top with the AR2CUT2 Once the shelter is in its final po...

Page 10: ...86 ROOF WIDTH 83 83 10 PLAN VIEW OVERALL DIMENSIONS AND GROUND FIXING POSITIONS Suggested size for concrete base 8 oversized on all 4 sides...

Page 11: ...anels regularly with soapy water Ensure all fittings are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS Email Sales nobutts com Web www nobutts...

Reviews:

Related manuals for SR8062-F