Commissioning
Mounting instruction
Function control
11
The receiver is connected via a connection cable to the system to be controlled. Please
observe the instructions of the system manufacturer when installing.
We strongly recommend establishing this connection via a central, easily
accessible plug connection (e.g. Tyco type (HTS) plug connection, series HE/
HB/HN/ HA, or a comparable one from a different manufacturer) to enable
a fast and precise error diagnosis for servicing and to be able to remove the
receiver without installation work.
The power for the receiver is supplied via the connection cable in most cases.
In general a ground cable (neutral conductor) must be installed for systems that have
never been operated with a radio control system. Otherwise the power for the receiver
electronics cannot be supplied! Please make sure that the operating voltage of the
receiver corresponds with the connection values of the system to be controlled. The
valid operating voltage is noted in the Annex.
A regular system test of the NBB radio control system is necessary for the maintenance
of operational safety. For single shift operation, we recommend performing this control
at least once a week. The control can be performed with the aid of the control lamps
located on the receiver. For this purpose, the transmitter must be ready for operation.
Only mount the receiver vertically to the external wall of the switch cabinet and make
sure that the antenna protrudes above the wall.
Make sure that the antenna is not partially or completely shielded by metal parts.
For installation in the cabin or switch cabinet, the antenna is installed on the outside
using the extension cable and attached with the mounting bracket as horizontal as
possible at a distance to the metal parts to be shielded.
The antenna should always be mounted so that it remains visible every time the loca-
tion of the transmitter is changed.
Falsch
Richtig
Falsch
.
Richtig
Installation for rotating tower crane.
Mount antenna with extension cable horizontally for
rotating tower crane
RIGHT
WRONG
WRONG
RIGHT
Above all make sure that no-one is in the danger zone.
Risk of accident!
Only switch the receiver on - the transmitter should remain switched off.
Put the transmitter into operation by pressing the “START/ON/HORN” key.
Now check the commands (always start with the lowest level) and the correct
response of the system to be controlled.
STOP control
. Press the STOP key on the transmitter. Afterwards check whether
the system to be controlled performs the stop operation sequence, i.e. whether it
switches off (shutoff time depends on application).
Summary of Contents for Nano-M SMJ
Page 11: ...10 Variations Receiver Compact M Compact MA Compact MB Compact MC Compact MD...
Page 19: ......