background image

GEN4065 4000 Surge Watts/3250 Running Watts Portable Generator  

15  

 

 

USING THE GENERATOR 

                                                                                

   

• USE THIS GENERATOR ONLY OUTDOORS IN NON-CONFINED AREAS. DO NOT SECURE THE GENERATOR WITH A CHAIN OR ROPE, AS 

THIS WILL MAKE IT DIFFICULT TO MOVE IN AN EMERGENCY. 

• Keep at least several feet of clearance on all sides to allow proper ventilation for this generator. 
 

After the engine has been running for several minutes, electrical devices may be connected to this generator. 
 

AC Usage 

 
Electrical devices running on AC current may be connected according to their wattage requirements. The rated (running) and surge wattage for this 

Model GEN4065 4000 Surge Watts / 3250 Running Watts Portable Generator is 3,250 and 4,000 respectively. 

 
Model GEN4065 Rated (Running) Wattage 

3250 

Model GEN4065 Surge Wattage 

4000 

 

The rated (running) wattage corresponds to the maximum wattage a generator can output on a continuous basis. 

 
The surge wattage corresponds to the maximum amount of power a generator can output for a short time. Many electrical devices, such as a 

refrigerator, require short bursts of extra power for starting and stopping fan motors, etc., in addition to their listed rated wattage. Motorized devices 

typically require more than their rated wattage for startup. The surge wattage ability of a generator allows for this extra power requirement. 

 
The total running wattage requirement of the electrical devices connected to a generator should not exceed the rated wattage of the generator itself. 

To calculate the total wattage requirement of the electrical devices to be connected, look up the rated (running) wattage of each device and add 

these numbers together to find the total wattage that all of the devices together will draw from the generator. If the total wattage of the selected 

devices exceeds the rated wattage of the generator, DO NOT connect all of the devices. Select a combination of the electrical devices that will have 
a total wattage less than or equal to the rated wattage for the generator. 

 
                                                                                

   

This generator can run at its surge wattage capacity for only a short time. Connect electrical devices requiring a rated (running) wattage 

equal to or less than the rated wattage of this generator. Never connect devices requiring a rated wattage equal to the surge wattage of a 
generator.
 
 

A device's rated (running) wattage should be listed somewhere on the device itself and/or in its manual. If the wattage specification for a device is not 

available, the wattage can be calculated by multiplying the Voltage requirement (120 or 240) by the Amperage drawn. 

 

Watts = Volts x Amperes 

 

Or, the wattage required by a device can be estimated by using the following chart. The chart provides only estimates and it is better to know the 

exact wattage of each electrical device to be powered by this generator. 

 

 

 

 

 
 

Electrical Device 

Rated (Running) Watts 

Additional Surge Watts 

air compressor (1 - 1/2 HP) 

2500 

2500 

airless sprayer (1/3 HP) 

600 

1200 

coffee maker 

1500 

computer w/17 inch monitor 

800 

deep freezer 

500 

500 

electric drill (1/2 HP) 

1000 

1000 

furnace fan blower (1/2 HP) 

800 

1300 

hot plate 

2500 

microwave oven (1000 watt) 

1000 

quartz halogen work light 

1000 

refrigerator/freezer (18 Cu. Ft.) 

800 

1600 

saw - circular (7 1/4 inch) 

1500 

1500 

stereo receiver 

450 

electric stove - single element 

1500 

sump pump 

800 

1200 

television (27 inch color) 

500 

well water pump (1/3 HP) 

1000 

2000 

window air conditioner (10000 BTU) 

1200 

1800 

window fan 

300 

 

600 

Connect electrical devices to this generator 

according to the following procedure: 

 
Allow the engine to run for several minutes after it 

has been started. 

 

Confirm that the electrical device is switched off 
prior to plugging it into this generator.  

Meijer.com

Summary of Contents for GEN4065

Page 1: ...that may occur We reserve the right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN TH...

Page 2: ...ts 3250 Running Watts Portable Generator FEATURES 4 Stroke OHV Engine Recoil Start 6 5 HP Gasoline Engine Automatic Low Oil Shutdown 2 120 Volt A C Outlets 1 12 Volt D C Outlet 4 Gallon Fuel Tank Engi...

Page 3: ...contiguous states excluding the states with high altitude areas identified in 40 CFR part 1068 Appendix III To exercise this warranty DO NOT RETURN TO RETAILER Instead call Customer Service toll free...

Page 4: ...ons you do not understand This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or deat...

Page 5: ...SECURE THE GENERATOR WITH A CHAIN OR ROPE AS THIS WILL MAKE IT DIFFICULT TO MOVE IN AN EMERGENCY Keep at least several feet of clearance on all sides to allow proper ventilation for this generator Che...

Page 6: ...least several feet of clearance on all sides of this generator during operation Do not enclose this generator in any structure Usage Misuse of this generator can damage it or shorten its life Use this...

Page 7: ...GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator 7 Meijer com...

Page 8: ...65 4000 Surge Watts 3250 Running Watts Portable Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator Meijer...

Page 9: ...able Generator Verify that all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETA...

Page 10: ...nd controls of this generator 9 AC Circuit Fuse 10 AC Circuit Fuse 11 120 Volt AC Output Socket 12 120 Volt AC Output Socket 13 12 Volt DC Output Socket 14 DC Circuit Fuse 1 Fuel Tank Cap 2 Control Pa...

Page 11: ...nkcase The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 20 fluid oz 0 59 L for this Model GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator Add the...

Page 12: ...ecause gasoline can expand do not fill the fuel tank to the very top 4 Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth Model GEN4065 Fuel Tank Capacity...

Page 13: ...vel currently in the fuel tank If necessary add fresh unleaded gasoline with an octane rating of 87 or higher according to Step 2 Add Gasoline of the Using this Generator for the First Time section of...

Page 14: ...sized cord can overheat short out and cause a fire Usage Do not use fuel stabilizers with this generator doing so could cause damage to the generator or decrease the fuel and operating efficiency of t...

Page 15: ...total wattage of the selected devices exceeds the rated wattage of the generator DO NOT connect all of the devices Select a combination of the electrical devices that will have a total wattage less t...

Page 16: ...lt outlet Connect 12 Volt DC loads to the 12 Volt outlet Even though this generator has an overall rated wattage of 4000 do not attempt to draw more than 3500 Watts from the 120 Volt outlet Draws high...

Page 17: ...enerator Failing to use the correct procedure can cause a battery to explode seriously injuring anyone nearby Keep heat sparks flame and smoking materials away from the battery To connect 12 Volt batt...

Page 18: ...ocedures according to the schedule in Figure 7 Never perform maintenance procedures while this generator is running Allow this generator to cool before commencing any maintenance procedures Keep heat...

Page 19: ...ery 100 hours of use time The oil capacity for this Model GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator engine is 20 fluid oz 0 6 L To drain the oil from this generator It is necessar...

Page 20: ...and install a new spark plug A F6TC spark plug such as NGK BPR5ES is recommended 4 Measure the spark plug electrode gap with a gauge The gap should be 0 028 0 031in 0 7 0 8mm See Figure 9 5 If re usin...

Page 21: ...trouble persists call our customer help line at 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time Symptom Cause Solution Engine switch is set to off Set engine switch to on Fuel valve is turned to c...

Page 22: ...GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator 22 GEN4065 4000 SURGE WATTS 3250 RUNNING WATTS PORTABLE GENERATOR PARTS DIAGRAM Meijer com...

Page 23: ...som 2 17 Bolt GB T5789 M6 12 8 18 Tank Cock 1 19 Fuel Pipe 1 20 Muffler Guard Cover 1 21 Bolt GB T5789 M6 16 2 22 Muffler 1 23 Bolt GB T16674 M8 20 3 24 Muffler Bracket 1 25 Nut GB T6184 M8 12 26 Engi...

Page 24: ...GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator 24 GEN4065 2011 08 Meijer com...

Reviews: