The small combustion load of the Combi Wok burner is 4,5 kW.
This results in the following flow values:
Earthgas H, E (G20)
0,48 m
3
/h
Earthgas L, LL (G25)
0,55 m
3
/h
Liquid gas
(G30)
0,35 kg/h
The appliance is operated in full combustion with fixed nozzles without adjustment.
The Wok burner has no small combustion adjustment.
It operates gradual from off (out) to in (in).
For the Combi Wok burner and the pilot flame the small combustion quantity is regulated for liquid gas with
fixed nozzles. For earhgas the nozzles are adjusted.
3.
Instruction of Users
The user must be instructed how to operate the appliance. The instruction for use must be kept to the user.
The user must be told that after construction changes in the room, which affects the combustion supply, the
operation control must be carried out.
4.
Operation
4.1 Operation elements
A
A= Gas cock with handle
4.2 Start up Wok burner
Before operation the main gas cock on the appliance must be opened.
Then press the knob of the safety tap “A“ in and keep the knob pressed in.
With ignition pistol start up pilot flame. After pilot flame burns knob “A“ to remain pressed in for 15 - 20
seconds. If after releasing knob “A“ the pilot flame goes out, you have to repeat the ignition process.
Now turn gas valve handle “B“ anti clockwise to position “ON“, the Wok burner will ignite.
Attention! Do not lean over main burner during ignition process.
The high flame could lead to burns.