background image

Gas - Meritus                                                                                                                     GB – Gas Range Series 

 

FRM-PDE-03-04 

 

Burner 5.5 kW (D Type) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO 

PART CODE 

DESCRIPTION 

QTY 

PD.2437A1 

Frame Breaker 5.5 kW 

PD.2440A 

Open Burner Casing 5.5 kW 

PD.2482 

O-Ring Seal 

PD.2431 

Open Burner Bearing 

PD.2433A 

Open Burner Ventury 

PD.9300 

Air Regulation Bush 

PD.2503A 

Nozzle Open Burner 5.5 kW Ø 1.15 (LPG) 

PD.2505A 

Nozzle Open Burner 5.5 kW Ø 1.80 (LNG) 

PD.9638 

Nozzle Holder 

GS.3895B 

Thermocouple 9x1 600mm w/Aluminized Tip 

10  PD.2276 

Pilot Nozzle Ø 0.25mm (LPG) 

GS.3828 

Pilot Nozzle Ø 0.35mm (LNG) 

11  PD.2481 

Pilot Burner for Open Burner 

 

 

 

 

Fig. 10 

Table 6 

  NAYATI 

19 

20151125 

 

 

Summary of Contents for NGR 8-75

Page 1: ...R 6 Open Burners with Oven NGTR 4 75 MR 2 Open Burners with Open Cabinet NGTR 8 75 MR 4 Open Burners with Open Cabinet NGTR 12 75 MR 6 Open Burners with Open Cabinet Gas Range Series Note The picture...

Page 2: ...Range Series is excellent choice to cook In order to obtain maximum benefits of this appliance please read this manual instruction carefully Please notice the warnings and safety instructions to keep...

Page 3: ...ta Plate 12 Overall Dimension 13 Components List 18 Handling and Installing 23 Packaging and Transport 24 Handling and Lifting 24 Safety Devices and Accessories 24 Position and Fixing 25 Gas Supply Co...

Page 4: ...complete picture of the information provided if necessary Warning Signs and Symbols Warning Warnings are indicated with a pictogram and a signal word The type and source of the risk as well as the con...

Page 5: ...ad damage User sign information must be read by user Technician sign information must be read by technician CE Certification The appliance have a license of CE Certificate Symbols Symbols Meaning Expl...

Page 6: ...ce sold or transferred elsewhere make sure this book goes with it Therefore the new user can read about its functions and other relevant information Procedure for Requesting Service and Warranty Reque...

Page 7: ...appliance in wet or humid room or condition such in rain or near water leaks etc 7 DO NOT use the appliance for drying clothes paper or living animals 8 DO NOT use the appliance to heat non food produ...

Page 8: ...5 kW E Type 10 kW F Type 3 5 kW C Type 5 5 kW D Type 7 5 kW E Type 10 kW F Type Gas Connection Gas Oven Burner 6 5 kW 6 5 kW Working Temperature C 100 310 7 steps 100 310 7 steps Gas Power see Overall...

Page 9: ...20 3 x 305 x 620 Gas Open Burners each of open burner 3 5 kW C Type 5 5 kW D Type 7 5 kW E Type 10 kW F Type 3 5 kW C Type 5 5 kW D Type 7 5 kW E Type 10 kW F Type 3 5 kW C Type 5 5 kW D Type 7 5 kW E...

Page 10: ...NGR 8 75 MR 2C2F 2 2 1 33 5 NGR 8 75 MR 4D 4 1 28 5 NGR 8 75 MR 2D2E 2 2 1 32 5 NGR 8 75 MR 2D2F 2 2 1 37 5 NGR 8 75 MR 4E 4 1 36 5 NGR 8 75 MR 2E2F 2 2 1 41 5 NGR 8 75 MR 4F 4 1 46 5 NGR 12 75 MR 6C...

Page 11: ...R 2E 2 15 NGTR 4 75 MR 1E1F 1 1 17 5 NGTR 4 75 MR 2F 2 20 NGTR 8 75 MR 4C 4 14 NGTR 8 75 MR 2C2D 2 2 18 NGTR 8 75 MR 2C2E 2 2 22 NGTR 8 75 MR 2C2F 2 2 27 NGTR 8 75 MR 4D 4 22 NGTR 8 75 MR 2D2E 2 2 26...

Page 12: ...current gas setting nominal data gases table categories and pressures for other CE countries Technical Plate reports warnings in European languages and destined languages Technical plate reports warn...

Page 13: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 Overall Dimension NGR 8 75 MR Fig 4 NAYATI 13 20151125...

Page 14: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 NGR 12 75 MR Fig 5 NAYATI 14 20151125...

Page 15: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 NGTR 4 75 MR Fig 6 NAYATI 15 20151125...

Page 16: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 NGTR 8 75 MR Fig 7 NAYATI 16 20151125...

Page 17: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 NGTR 12 75 MR Fig 8 NAYATI 17 20151125...

Page 18: ...2431 Open Burner Bearing 1 5 PD 2432A Open Burner Ventury 1 6 PD 9300 Air Regulation Bush 1 7 PD 2414A Nozzle Open Burner 3 5 kW 0 90 LPG 1 PD 2502A Nozzle Open Burner 3 5 kW 1 50 LNG 1 8 PD 9638 Noz...

Page 19: ...pen Burner Bearing 1 5 PD 2433A Open Burner Ventury 1 6 PD 9300 Air Regulation Bush 1 7 PD 2503A Nozzle Open Burner 5 5 kW 1 15 LPG 1 PD 2505A Nozzle Open Burner 5 5 kW 1 80 LNG 1 8 PD 9638 Nozzle Hol...

Page 20: ...Burner Bearing 1 5 PD 2434A Open Burner Ventury 7 5 1 6 PD 9300 Air Regulation Bush 1 7 PD 2426A Nozzle Open Burner 7 5 kW 1 35 LPG 1 PD 2507A Nozzle Open Burner 7 5 kW 2 15 LNG 1 8 PD 9638 Nozzle Ho...

Page 21: ...Burner Bearing 1 5 PD 2434A Open Burner Ventury 1 6 PD 9300 Air Regulation Bush 1 7 PD 2515 Nozzle Open Burner 10 kW 1 50 LPG 1 PD 2516 Nozzle Open Burner 10 kW 2 35 LNG 1 8 PD 9638 Nozzle Holder 1 9...

Page 22: ...older for Oven 1 6 PD 4052FD Gas Knob 1 7 PD 4055O1A Ring Gas Knob for Oven 1 8 PD 9897B Adaptor Axis 1 9 GS 3060A Eurosit 100 340C 1 10 GS 3720B Piezo Igniter 18mm 1 GS 3720B 1 Ring for Piezo Igniter...

Page 23: ...s supply is sufficient to operate this appliance 4 Install the appliance by using Qualified Gas Filter 5 Before testing put the appliance in a good ventilated room and keep all flammable material away...

Page 24: ...he means of transport securely to prevent undesirable shifting Handling and Lifting The appliance can be handled using fork lift or hook equipment of suitable load carrying capacity Before lifting che...

Page 25: ...ire resistant materials made 8 Install the appliance separately or side by side with other appliance according to recommended range 9 Put Gas Range Series on solid flat and horizontal floor 10 Adjust...

Page 26: ...ange Series nominal heat input maintenance and gas conversion DO NOT improve Gas Range Series performance and increase nominal heat affirmed by the manufacturer Control heat input by using gas counter...

Page 27: ...ectors and adjust correctly Primary Air Setting for each Main Burner 3 Spare injectors are available with the appliance 4 Make sure the diameter printed on each injector in 1 100 of a millimeter 5 Con...

Page 28: ...b Pilot Burner Unscrew the bolt and change the pilot nozzle with the new gas type WARNING After doing conversion please remember to Attach an indelible sticker on technical data plate with the new ins...

Page 29: ...04 Primary Air Adjustment 1 Open Burner a Unscrew the bolt with an appropriated screw driver b Move Primary Air Adjuster in order to reach the distance which according to the table H c Retighten the...

Page 30: ...0 25 G20 1 85 20 Adjusted 2 0 35 25 G25 2 00 20 Adjusted 2 0 35 1 90 25 Adjusted 2 0 35 G25 1 25 Open Burner Type Gas Type Nozzle D max P mbar By pass Screw Primary Air H mm Pilot Nozzle mm 7 5 kW E...

Page 31: ...Air Adjuster in order to reach the distance which according to the table H c Retighten the screw cap again Oven Burner Type Gas Type P mbar Nozzle mm Primary Air H mm Pilot Nozzle mm 6 5 kW G30 G31 2...

Page 32: ...authorized mechanic 3 User is only responsible for daily routine cleaning for maintenance 4 Qualified mechanic must do operations related to installation and maintenance according to Regulation in fo...

Page 33: ...or Rear Open Burner to turn ON OFF the front Burner A2 Gas Valve for Front Open Burner to turn ON OFF the rear Burner C Thermostat Control Knob for Oven to open and close the gas supply of Oven D Piez...

Page 34: ...by using Piezo Igniter 2 Push the Thermostat Control Knob for about fifteen seconds 3 Check the Pilot flame through the hole in base oven panel 4 If the pilot flame extinguishes repeat the above steps...

Page 35: ...top with soft detergent and let stand for 5 minutes to allow chemical cleaning action to take place Use stiff brush or wooden scraper to lost baked on grease and carbonized deposits Remove dissolved d...

Page 36: ...n the appliance NEVER wash the appliance with direct high pressure jet water If the cooker will not used for a long time briskly rub the steel part slightly with a damp cloth and Vaseline oil After th...

Page 37: ...The burner flame yellow The Primary Air Adjuster closed Check and open the Primary Air Adjuster The Burner is dirty Clean with brush 3 The burner does not light The gas cook damaged Check and replace...

Page 38: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 CE Certificate CE Certificate NAYATI 38 20151125...

Page 39: ...ti com SURABAYA Jl Kertajaya No 41 43 Surabaya 60281 Indonesia T 62 31 503 5844 503 5049 F 62 31 503 1933 E resto sby nayati com DENPASAR Jl Gunung Semeru No 26 A Denpasar 80119 Bali Indonesia T 62 36...

Reviews: