Gas - Meritus GB – Gas Range Series
FRM-PDE-03-04
2.
Oven Burner
a.
Unscrew the bolt with an appropriated screw driver
b.
Move Primary Air Adjuster in order to reach the distance which according to the table
(H)
c.
Retighten the screw cap again.
Oven Burner
Type
Gas Type
P (mbar)
Nozzle
Ø (mm)
Primary Air H
(mm)
Pilot Nozzle
Ø (mm)
6.5 kW
G30/G31
28-30/37
1.30
20
Ø 0.20
50
1.13
14
Ø 0.20
G20
20
1.95
13
Ø 0.35
G25
20
2.10
13
Ø 0.35
25
2.00
13
Ø 0.35
Fig. 18