background image

 

 

BLE, TECHNOTON DUT-E, GL-TV) 
Bluetooth connection for up to 4 wireless temperature and humidity 
sensors (ADM31, ESCORT TL-BLE) 

no 

Bluetooth connection for ADM32 wireless tilt angel sensors 

no 

Bluetooth connection for TECHNOTON GNOM DDE wireless axle load 
sensors 

no 

Bluetooth connection for TECHNOTON DFM wireless fuel level sensor 

no 

Bluetooth connection for ELM327 diagnostic adapter 

no 

Transparent mode

yes

 

Unloading of ddd-files from «Shtrikh», «Mercuriy», «VDO Continental», 
«Atol»

8

  tachographs 

yes 

Events sending on tachograph state change 

yes 

Driver display DV-01 support 

yes 

Text messages display received from the server or by SMS on DV-01 driver 

display 

yes 

Built-in “Autoinformer” function 

yes 

Support of 

 

route sign boards “ITLINE” and “Integral”  

yes 

Display of information about current route, current and next stop on the 
DV-01 driver display when the “Autoinformer” function is on 

yes 

Monitoring compliance with speed limits by geofences 

yes 

Display of information about 

 

set speed limit and overspeed warnings on 

the DV-01 driver display 

yes 

Display of information about the fuel level in liters from 4 LLS fuel level 

sensors on the DV-01 driver display 

yes 

Connection of  passenger flow meters  “PP-01” and “Avtokonduktor”  

yes 

Camera connection support, sending pictures to the server upon the 

request 

yes 

Using of information from tire pressure sensors “Pressure Pro”, “TPMS 6-

13” (from “Parkmaster”), “B-Tag” (from “Bridgestone”), TM508T22U and 
“TD 18, 20, 21” 

yes 

Operating with

 

breathalyzer “Alcogran AM-525” 

yes 

Interface for connection of digital temperature sensors 

1-Wire 

The maximum number of connected digital temperature sensors by 1-Wire 

Events formation about reduce/increase of temperature 

yes 

Reading TouchMemory key codes and drivers identifying by 1-Wire 

yes 

The maximum number of TouchMemory key codes stored in the device 
memory without SD-card 

510 

Connection of microphone and loudspeaker to establish a speakerphone 
with a driver and microphone listening 

yes 

Resistance and power of the connected loudspeaker 

4 ohm – from 1,5 up to 5 watts 

8 ohm – from 1,0 up to 3  watts 

Connection to buzzer output line for notification of an incoming call 

yes 

Performance specifications

 

Storage temperature with the battery

9

, °C 

0 … +40 

Storage temperature without the battery

9

о

-40 … +85 

Operating temperature with the battery

10

о

-20 … +60 

Operating temperature without the battery

10

о

-40 … +85 

Temperature at which the battery is possible to charge, 

o

0 … +50 

Maximum allowable humidity level at 35 

o

C, % 

95 

Maximum allowable overload during impacts, g 

24 

Design features of the device 

External GLONASS/GPS and GSM antennas 

yes 

Plug for connection to the computer 

miniUSB 

Connectors for GLONASS /GPS and GSM antennas 

SMA 

Summary of Contents for SIGNAL S-2654

Page 1: ...GPS GLONASS TRACKING EQUIPMENT SIGNAL S 2654 Operations manual Installation and connection of the device v1 0 MOSCOW 2020...

Page 2: ...terested in constantly improvement of the manufactured products quality Please contact our technical support by email address support navtelecom ru should you have any questions or problems with the d...

Page 3: ...18 2 3 GSM and GLONASS GPS antennas connection 20 2 4 Power connection 20 2 5 Universal inputs connection 21 2 5 1 Analog sensors connection 21 2 5 2 Discrete sensors connection 21 2 5 3 Pulse frequen...

Page 4: ...c mode control of cargo safety by comprehensive measures improving driver and passenger s safety 1 3 Operational principles The device during its operation continuously monitors the status of the conn...

Page 5: ...olonged overvoltage up to 200V yes Current consumption at 12 V voltage in operation mode on average3 mA 80 Current consumption at 12 V voltage with turned off GLONASS and GSM modules is no more than m...

Page 6: ...D card no less than 2 000 000 per 1 Gb Accelerometer Accelerometer with built in configured shock sensors displacement and tilt sensors yes Measured acceleration range g 24 Acceleration errors in the...

Page 7: ...a encryption according to the AES128 standard in data transfer yes Real mileage measurement algorithm with the terrain features yes Sensors selection for coordinate averaging yes Configuration of data...

Page 8: ...ort sending pictures to the server upon the request yes Using of information from tire pressure sensors Pressure Pro TPMS 6 13 from Parkmaster B Tag from Bridgestone TM508T22U and TD 18 20 21 yes Oper...

Page 9: ...annot be used in high humidity high and low ambient temperatures Operation is permitted under the conditions specified by the manufacturer Not to hit not to deform not to disassemble not to close cont...

Page 10: ...on of 2 way speakerphone interface SMA connector for connecting a GSM antenna on the left SMA connector for GLONASS GPS antenna connection on the right On the side of the device unit figure 2 is locat...

Page 11: ...1 2 5 Fuse holder 1 6 14 pin connector of Microfit 14 with two power wires 1 7 6 contact connector of Microfit 6 type 1 8 4 contact connector of Microfit 4 type 1 9 Cable set of 10 installation wires...

Page 12: ...Figure 9 4 pin connector of Microfit 4 type Figure 10 Interface cable with MiniUSB connector Some cases may require connection of additional equipment not included in the standard equipment set for e...

Page 13: ...Figure 11 Fuel level sensor Figure 12 Tachograph Figure 13 External LED Figure 14 Temperature sensor...

Page 14: ...angent G 2500 Figure 16 TouchMemory contact key reader The manufacturer reserves the right to complete the devices with equipment whose set appearance and characteristics differ from those shown in th...

Page 15: ...em LED indicator 4 GLONASS GPS LED indicator 5 GSM antenna connector 6 GLONASS GPS antenna connector 7 fixing hole 8 4 pin connector 9 14 pin connector 10 6 pin connector 11 MiniUSB connector 12 SIM c...

Page 16: ...Figure 19 Figure 20...

Page 17: ...1 Hz to 2000 Hz and analog voltage from 0 V to 31 V FLS impulse fuel consumption sensors DRL buttons or switches Attention It is prohibited to apply a voltage more than 50 V to the device universal i...

Page 18: ...bus adapter tachographs RFID MODBUS devices etc The digital interface RS 485 is designed for connection of various devices transmitting and receiving information on this interface for example fuel le...

Page 19: ...of the connection and settings of the device it is not recommended to directly include actuating devices in the output circuits It is advisable to do this at the final stage of verification The power...

Page 20: ...ion If the SIM card is locked with a PIN code it is necessary to unlock it by inserting the SIM card into a mobile phone or specify the PIN code of this card in the device settings in the Data transmi...

Page 21: ...ion 2 4 Power connection The power supply of the system is carried out from the on board network of the car which should within the limits indicated in Table 1 in the section Basic technical character...

Page 22: ...ltage has to be monitored the voltage measurement profile must be set in the inputs setting In this case the function of adjustable averaging of measured values and the setting of the threshold level...

Page 23: ...resistor when operating with sensors which operates on by ground Rpu CPU_adc R1 R2 UIN C1 CPU_pull up VDD Figure 28 Connection of normally open NO sensors Rpu CPU_adc R1 R2 UIN C1 CPU_pull up VDD Figu...

Page 24: ...cle ignition line and make the appropriate setting in the configuration However such connection is not mandatory In addition to the source of notifications about turning on and turning off events the...

Page 25: ...ry to set the threshold level of fixation correctly in order the device correctly determine the frequency or calculate the pulses Connecting pulse or frequency sensors the output of which is implement...

Page 26: ...n it connects the external load to the power supply to the ground The character of the controlling signal depending on the chosen mode can be permanent signal or periodic Settings of the outputs are m...

Page 27: ...motive LED lamps It is only necessary to select the LED lamp under the desired voltage of the on board vehicle network 4 2 3 1 14 7 13 6 12 5 11 4 10 3 9 8 2 1 6 5 4 3 2 1 Fuse 1 GND Car battery 1 2 k...

Page 28: ...wer contacts are always marked as 30 87 and 87a The 30th pin is always in the relay Without applying voltage to the winding contacts it is permanently closed to contact 87a If a signal is applied to t...

Page 29: ...into it at the manufacturing plant by which the device identifies this sensor Saving the key codes in the device s memory allows to use identification when changing the security mode activating the ou...

Page 30: ...t all sensors must be connected to one common two wire cable called as bus or trunk It is important not to leave open the end of the bus that is opposite to the connected device it should be closed by...

Page 31: ...connector The nominal input voltage of the audio signal at the device LOUT output is 500 mV If the amplifier has 2 channels then to increase the power you can connect both amplifier channels in paral...

Page 32: ...Such a reader allows to receive data from the CAN bus of the car without physically connecting and breaking the insulation of the wires thus avoiding problems with warranty service for new cars The d...

Page 33: ...Note There can be several CAN buses in the vehicle while information required to the user can be transmitted in different buses Since the terminal has only one CAN interface it is impossible to recei...

Page 34: ...in the range from 5 to 12 V relative to the sensor supply On the Rx line the voltage will be close to 0 2 12 RS 485 interface connection The digital interface RS 485 is designed to connect devices tra...

Page 35: ...on when the speakerphone is established with the device An electret microphone capsule is connected to pins 1 MIC and 3 MIC This microphone capsule is used in computer microphones in a compact enclos...

Page 36: ...1 second off There is a registration in the cellular network of the operator Weak signal 2 short flashes 1 second off There is a registration in the cellular network of the operator Medium quality si...

Reviews: