1. Verify the power supply being used, to match the voltage on the nameplate.
2. Ensure that the pump is switched off prior to connecting to the power source. 
3. Check for proper oil level, or change if needed.
4. Remove the oil fill cap, filling oil to the level in between the two oil sight glass lines, as shown in the 
    drawing below. For specific pump oil volume, please see the technical specification table.

Note: In order to avoid personal injury, please carefully read and follow the instructions in this user 
         manual and the user guide of the pump.

NAVTEK

VACUUM  PUMPS  ARE  NOT  ALLOWED  TO  BE  USED  FOR  A3  OR  FLAMMABLE 

REFRIGERANTS.

1. NEVER CONNECT A VACUUM PUMP TO  A  PRESSURIZED SYSTEM. Always check to make 
    sure that system and piping pressure is NOT ABOVE ATMOSPHERIC PRESSURE.
2. When handling refrigerants, please wear an eye-protection such as safety glasses or goggles. 
3. Avoid direct physical contact with refrigerants, you will get burned. 
4. When connecting the power source, all equipments must be grounded in order to prevent  
    electrical hazards. 
5. When the pump is in operation, the enclosure surfaces will be hot. Do not touch the oil box or the 
    motor case. Allow adequate ventilation space for heat dissipation. 
6. When using R-32, 1234yf or other flammable refrigerants, use an explosion proof electrical outlet.
7. Keep pump dry and away from water, mud, and dirt at all times.
8. Operating pump with intake fittings open to the atmosphere must not exceed 3 minutes. 

Power outlet must be grounded.