background image

TEKCOM Industries Limited 

Page 4 of 6 

ALIGNMENT AND ADJUSTMENT 

 

This transceiver is completely aligned at the factory and does not require any adjustments for installation. 
However it is considered as good practice to verify that none of the adjustments are changed.   
 
Do not adjust any circuitry in this radiotelephone unless you understand the circuit operation and have 
experience in adjusting radiotelephone.  Tampering with the radiotelephone may upset the alignment and 
lower its performance. 
 

Test Equipment Required: 

 

!"

Regulated DC power supply, 15V,7A   

!"

Audio signal generator,10Hz~3kHz 

!"

Digital multimeter 

!"

Deviation meter 

!"

Frequency counter,0~500MHz high impedance 

!"

Oscilloscope 

!"

RF power meter, 

30W 

!"

High frequency standard generator,>500MHz 

!"

Tracking generator,>500MHz 

!"

Distortion analyzer 

!"

Audio level meter 

!"

T-coupler 

!"

Alignment drivers, etc. 

ADJUSTMENT PROCEDURE 

 

Step Item 

Adjustment 

Procedure 

TX Frequency 

VC2 

Adjust VC2 to obtain demanded TX frequency. 

TX Power Hi 

VR5 

Adjust VR5 to obtain demanded TX power 23

±

2W. 

TX Power Lo 

VR6 

Adjust VR6 to obtain demanded TX power 0.8

±

0.1 W. 

TX. Dev. 

VR3 

1. 

Inject an audio frequency (AF) -20dBm. 

2. 

Adjust VR3 to obtain maximum TX deviation 

5kHz. 

3.  Check MIC modulation sensitivity, which should be 

2.5~10mV. 

5 RX 

L10,L11,L12, 

L13,L14,T1,T2 

1.  Check RX sensitivity if it is normal. 

2.  Adjust L10, L11, L12, and L13 to obtain Best Frequency 

response. 

3.  Adjust L14,T1 and T2 to obtain Best RX sensitivity 

 

 
 
 

Reviews: