3.2.
By external keypad
Long press of keypad (2-3 seconds)
By long pressing the external keypad (2-3 seconds), the video interfaces witches the input
from the factory video to the inserted video sources. If all inputs are activated by dip switch
settings, the order is the following:
Factory video
Left (V1)
Right (V2)
factory video
Each long press will switch to the next enabled input. Inputs which are not enabled will be
skipped.
Note: The interface switches after releasing the switch (after long pressure).
Short press of keypad (only if DIP 1 is set to ON)
By short pressing the external keypad, the video interfaces witches from the factory video to
the front camera input and back to factory video.
4.
Specifications
BATT/ACC range
7V - 25V
Stand-by power drain
12mA
Power
250mA @12V
Video input
0.7V - 1V
Video input formats
NTSC/PAL
Temperature range
-40°C to +85°C
Dimensions video-box
118 x 23 x 105 mm (W x H x D)