![Navistar N9 Diagnostic Manual Download Page 20](http://html1.mh-extra.com/html/navistar/n9/n9_diagnostic-manual_3616391020.webp)
16
1 DIAGNOSTIC TROUBLESHOOTING PROCEDURES
SPN
FMI
Sub-section
Condition Description
2659
10
AMS (page 381)
EGR Slow Response Fault
2659
14
AMS (page 381)
EGR System flow rate error during Air Management Test
2659
20
AMS (page 381)
EGR High Flow Rate detected
2659
21
AMS (page 381)
EGR Low Flow Rate detected
2791
2
EGR (page 1074)
EGR feedback communication fault
2791
3
EGR (page 1074)
EGRV supply voltage is too HIGH
2791
4
EGR (page 1074)
EGRV supply voltage is too LOW
2791
7
EGR (page 1074)
EGR Valve unable to achieve commanded position
2791
8
EGR (page 1074)
EGR valve not receiving ECM PWM signal
2791
12
EGR (page 1074)
EGR Valve Internal self test fault
2791
14
EGR (page 1074)
EGR valve Initialization Fault
2797
6
INJ (page 1365)
Injector Control Group 1 - short circuit (INJ 1, 2, 3)
2798
6
INJ (page 1365)
Injector Control Group 2 - short circuit (INJ 4, 5, 6)
3031
2
DEFTLT (page 746)
DEFTT signal erratic, intermittent or incorrect
3031
3
DEFTLT (page 746)
DEFTT signal Out of Range HIGH
3031
4
DEFTLT (page 746)
DEFTT signal Out of Range LOW
3055
2
INJ (page 1365)
ICP / IPR Adaptation In-Range Fault
3061
31
CSER Exhaust warm up time fault
3216
4
NO
X
NOxIN signal Out of Range LOW
3216
10
NO
X
NOxIN signal abnormal rate of change
3216
13
NO
X
NOxIN Out of Calibration
3216
19
NO
X
NOxIN not detected on J1939
3216
20
NO
X
NOxIN signal drifted HIGH
3216
21
NO
X
NOxIN signal drifted LOW
3218
2
NO
X
NOxIN power supply signal erratic, intermittent or incorrect
3226
2
NO
X
NOxOUT signal erratic, intermittent or incorrect
3226
4
NO
X
NOxOUT signal Out of Range LOW
3226
10
NO
X
NOxOUT signal abnormal rate of change
3226
13
NO
X
NOxOUT Out of Calibration
3226
19
NO
X
NOxOUT not detected on J1939
3226
20
NO
X
NOxOUT signal drifted HIGH
3226
21
NO
X
NOxOUT signal drifted LOW
3228
2
NO
X
NOxOUT power supply signal erratic, intermittent or incorrect
3242
0
DPFIT (page 876)
DPFIT above Critical Temperature
3242
2
DPFIT (page 876)
DPFIT signal erratic, intermittent, or incorrect
Summary of Contents for N9
Page 2: ......
Page 4: ...II DIAGNOSTIC MANUAL...
Page 10: ...6 DIAGNOSTIC MANUAL...
Page 14: ...10 1 DIAGNOSTIC TROUBLESHOOTING PROCEDURES...
Page 42: ...38 1 DIAGNOSTIC TROUBLESHOOTING PROCEDURES 6 0 Cooling System Operational Checkout Procedure...
Page 43: ...1 DIAGNOSTIC TROUBLESHOOTING PROCEDURES 39 7 0 Lube Oil System Operational Checkout Procedure...
Page 51: ......