address of the PC where the Configurator is installed, 12500 - the IP port specified in the settings of the
configurator connections. After the above actions, the device will independently connect to the configurator via
the Internet and will be available for the remote configuration. To make a remote re-connection, you need to
send the COM5 command again
Please note that the PC's IP address must be real and visible from the Internet. It can be both dynamic
and static. To check the IP address all you need is to carry out the check from any PC connected to the Internet
via another connection. Click Start -> Run, enter the PING command and specify your IP address. For example,
PING 203.151.20.2:5001. If you see a response - IP address is real and visible from the Internet, if it is absent -
the operator granting access to the Internet provides IP from the virtual subnet, and in this case, to make a
remote connection to the device is impossible. In this case, use DYNDNS proxy to get a real IP address.
3.
Configuring when starting up for the first time.
When the power is on for the first time, the device does not have a configuration and tries to connect
to the configuration server. If the configuration has been previously uploaded to the cloud for this device IMEI,
automatic loading is performed, and after reboot, the device works in accordance with the loaded configuration.
NOTE!!! By default, the device is set to work with MTS SIM cards. This operation is possible only when
the MTS SIM cards are installed. Installation of the another operator’s SIM card is possible if this operator does
not require a specific APN.
Information about configuration upload to the cloud See the section of operation with the
configurator "CLOUD PANEL."
7.2.
RUNNING THE CONFIGURATOR PROGRAM
7.2.1.
«STATE MONITORING» PANEL
The configurator has an opportunity to display in real time the current state of all values measured by
the device and the current state of work.
In addition to the parameters display, the diagnosis of the device is also displayed in real time. This
window allows you to see what actions the device is taking and in the case of failure, you can quickly find the
cause.
All data are displayed in the dynamic mode. If a parameter is changed, it is immediately displayed on
the corresponding panel.
The parameter "Connection to the Server" assesses work of the communication channel. The first sign
of the parameter indicates the server with which the device (no. 1 and no.2) works, a second one - connection
to the specified server.
Evaluation of the data transmission is performed by the parameter "Data for transmission." If the
value differs from zero, there are data for transmission.
Only inputs enabled in the settings are displayed. Depending on the input type, the displayed data will
be different. For example, if the input is analog, the voltage measured in V is displayed, if the input is frequency
- the frequency in Hz is displayed, if the input is counter – the number of pulses is displayed, if the input is
discrete - an active/inactive state is displayed.
The outside temperature is taken from the connected digital sensors by 1-Wire bus. 8 is a maximum
number of sensors. The sensors’ addresses are assigned automatically when they are connected. The first
connected sensor will display the 1 temperature, the second one – 2 temperature, and so on. Therefore, the
sensors shall be connected one by one.