background image

address of the PC where the Configurator is installed, 12500 - the IP port specified in the settings of the 

configurator connections. After the above actions, the device will independently connect to the configurator via 

the Internet and will be available for the remote configuration. To make a remote re-connection, you need to 

send the COM5 command again 

Please note that the PC's IP address must be real and visible from the Internet. It can be both dynamic 

and static. To check the IP address all you need is to carry out the check from any PC connected to the Internet 

via another connection. Click Start -> Run, enter the PING command and specify your IP address. For example, 

PING 203.151.20.2:5001. If you see a response - IP address is real and visible from the Internet, if it is absent - 

the operator granting access to the Internet provides IP from the virtual subnet, and in this case, to make a 

remote connection to the device is impossible. In this case, use DYNDNS proxy to get a real IP address. 

3.

 

Configuring when starting up for the first time.  

When the power is on for the first time, the device does not have a configuration and tries to connect 

to the configuration server. If the configuration has been previously uploaded to the cloud for this device IMEI, 

automatic loading is performed, and after reboot, the device works in accordance with the loaded configuration. 

NOTE!!! By default, the device is set to work with MTS SIM cards. This operation is possible only when 

the MTS SIM cards are installed. Installation of the another operator’s SIM card is possible if this operator does 

not require a specific APN. 

Information about configuration upload to the cloud See the section of operation with the 

configurator "CLOUD PANEL." 

 

7.2.

 

RUNNING THE CONFIGURATOR PROGRAM 

7.2.1.

 

«STATE MONITORING» PANEL 

The configurator has an opportunity to display in real time the current state of all values measured by 

the device and the current state of work. 

In addition to the parameters display, the diagnosis of the device is also displayed in real time. This 

window allows you to see what actions the device is taking and in the case of failure, you can quickly find the 

cause. 

All data are displayed in the dynamic mode. If a parameter is changed, it is immediately displayed on 

the corresponding panel. 

The parameter "Connection to the Server" assesses work of the communication channel. The first sign 

of the parameter indicates the server with which the device (no. 1 and no.2) works, a second one - connection 

to the specified server. 

Evaluation of the data transmission is performed by the parameter "Data for transmission." If the 

value differs from zero, there are data for transmission. 

Only inputs enabled in the settings are displayed. Depending on the input type, the displayed data will 

be different. For example, if the input is analog, the voltage measured in V is displayed, if the input is frequency 

- the frequency in Hz is displayed, if the input is counter – the number of pulses is displayed, if the input is 

discrete - an active/inactive state is displayed. 

The outside temperature is taken from the connected digital sensors by 1-Wire bus. 8 is a maximum 

number of sensors. The sensors’ addresses are assigned automatically when they are connected. The first 

connected sensor will display the 1 temperature, the second one – 2 temperature, and so on. Therefore, the 

sensors shall be connected one by one. 

Summary of Contents for GT-20 PRO

Page 1: ...NAVISET GT 20 PRO IRIDIUM WiFi BT NAVISET GT 20 LITE TRANSPORT MONITORING TERMINALS 2016 Version 5 1 25 01 2016 USER GUIDE Exclusive partner ...

Page 2: ...pcs SD card support announcement device additional black box Yes No Possible connection of the driver s display Yes No Support of WiFi Bluetooth IRIDIUM GLOBALSTAR Yes No RS232 interface 2pcs 1 piece Gyroscope for inertial guidance option No Number of points of announcement device phrases Unlimited 0 pcs Number of configurable logical events Unlimited Up to 4 pcs Number of registers of data from C...

Page 3: ... speeds up cold start and increases accuracy HANDS FREE is a connection of any tablet PC based on Android to perform the functions of the driver s display loudspeaker communication and access to 3G and LTE data transfer networks 3 CORE CAPABILITIES We have been striving to create a high quality versatile customizable and inexpensive device for years NAVISET GT 20 is a top of our efforts which allo...

Page 4: ...f slots for SIM cards SD cards pcs 2 1 2 0 Number of SIM chips pcs optional 2 2 Voice interface for connection of loud speaker communication yes yes Bluetooth interface for the display optional yes no Sensor of changes of location in space accelerometer yes yes Gyroscope for inertial guidance optional yes no Black Box number of records 650000 174000 Interface for communication with the PC USB 2 0 ...

Page 5: ...an be replaced by STX3 or Gonets or Inmarsat in software The yellow color indicates the possible combinations of transmitters on the communication channels Combined transmitters can not operate simultaneously on the same channel Therefore the user should determine the initially set priorities of the communication channels The priority of the communication channel and the switching logic are descri...

Page 6: ...s advisable to set GSM as priority transmitter and 5 10 minutes for time of switching and testing of WiFi networks If WiFi appears from time to time it is better to let WiFi remain high priority and to transmit data via GSM only after filling the buffer the size of which is defined by the user 5 2 APPEARANCE AND HARDWARE VERSIONS OF NAVISET GT 20 All the necessary interfaces for connection are loc...

Page 7: ...ced only upon request Before ordering it is necessary to agree on prices and date of execution of the order Other versions are available only by special order At the same time the appearance and location of the connectors may differ from the above three versions 5 3 NAVISET GT 20 INTERFACES All modifications and versions have the same appearance except for the antenna connector the purpose of the ...

Page 8: ...m 0 to 10 kHz IN4 0 36V analog digital input frequency square signal from 0 to 10 kHz IN5 0 36V analog digital input frequency square signal from 0 to 10 kHz IN6 0 36V analog digital input frequency square signal from 0 to 10 kHz IN7 0 36V analog digital input frequency square signal from 0 to 10 kHz IN8 0 36V analog digital input frequency square signal from 0 to 10 kHz OUT1 IN 9 Output impedance...

Page 9: ...f the input and the input 5 Engine hour indicator the input function is designed to count the car engine running time running time of the vehicle and to count the driver s working time When an input voltage is positive the counter increases by 1 unit every second When the sum of 65 535 is reached the counter is reset to zero and the count starts afresh The counter value is transmitted explicitly 6...

Page 10: ...ICATOR Description of modes Is constantly on Data are being transmitted via a satellite Flashes once per second Initialization of the satellite channel Flashes 2 times per second for no longer than 2 sec There was a data communication error Is off Satellite modem is off 5 5 CONNECTION of the SENSORS and PERIPHERALS The most common types of connections are given in the following table Type of the c...

Page 11: ...g to the purpose of the contact See more detailed information in the specification for the handsfree 6 CONTROL AND CHANGE OF SETTINGS USING SMS COMMANDS To control and change the settings via SMS special set of commands is used These commands are sent from any authorized entered in the memory of the device phone List of available commands and their meanings are listed below Command Taken values CO...

Page 12: ...255 255 12500 After the command is executed the device will be reconnected to the specified address and send an SMS like Remote config 255 255 255 255 12500 COM6 PASS MAP Location information PASS is a current password set in the device Factory default value is 1234 MAP Web map 0 OpenStreet 1 Google EXAMPLE COM6 1234 0 After the command is executed СМС message with location data a link to the spec...

Page 13: ...will come COM17 PASS NUMOP Change the operator in roaming PASS is a current password set in the device Factory default value is 1234 NUMOP an index of the operator of the terminal memory from 1 to 5 EXAMPLE COM17 1234 2 switch to work with the second operator After the command is executed the confirmation Operator set to 2 will come COM18 PASS Check the list of the connection numbers PASS is a cur...

Page 14: ...on on a straight section 0 off 1 on DELTA angle of leeway 0 360 MOVETIME record time on the move MINSPEEDANGLE minimum speed of the drawing on turns 0 250 ANGLE angle of the drawing on turns FEVOL filtration when rebuilding 0 off 1 on EXAMPLE COM24 1234 0 5 3 7 0 After the command is executed the confirmation Data changed will come If you send an SMS COM24 1234 Current parameters will come in retu...

Page 15: ... Glonass GPS module WiFi module 5 Software update The configurator is designed to work with NAVISET GT20 GT50 transport monitoring terminals When the configuration device is connected the only parameters that can be used by this device are available The top button panel is the panel of additional configurator functionality button assignment from left to right 1 Switching of a user interface langua...

Page 16: ...you mouse over any element in the configurator description of the item and possible actions with is are displayed in this field Create a new configuration with the default parameters Open previously saved configuration from the file Save the configuration in a file Select a type of connection to the device Locally or via the Internet Monitoring of the status of all device parameters Configuration ...

Page 17: ...ote connection to the device via GPRS It completely replaces the direct cable connection to the device without restriction of the CONFIGURATOR program functionality To establish the connection click setting of connections in the drop down list of COM ports select Internet In the appeared window enter the port number through which IP connection will be produced For example 12500 If the computer has...

Page 18: ...t require a specific APN Information about configuration upload to the cloud See the section of operation with the configurator CLOUD PANEL 7 2 RUNNING THE CONFIGURATOR PROGRAM 7 2 1 STATE MONITORING PANEL The configurator has an opportunity to display in real time the current state of all values measured by the device and the current state of work In addition to the parameters display the diagnos...

Page 19: ...configured parameters For various modifications the data transmitters assigned to the channel are visually displayed on the panel of communication channels If in the section of Digital ports the satellite transmitter of the Inmarsat or GONETS type is selected as a connected device they will also be displayed on the panel of communication channels The basic parameters specify the server addresses w...

Page 20: ...mitter with the mouse up or down In the modification no 4 there is a possibility to choose combination of the IRIDIUM transmitter GlobalStar with the WiFi transmitter on the channel 1 or with GSM on the channel 2 Depending on the logic and conditions of operation the user selects the most optimal configuration of the transmitters To move IRIDIUM transmitter GlobalStar from one channel to another d...

Page 21: ... the stationary mode If within the specified time the motion sensor is inactive the device switches to stationary mode Package recording period while driving specifies the time interval at which data packets will be recorded when running speed is less than 10 km h Record packets in each m When the speed is more than 10 km h packet recording interval is determined by the traveled distance which is ...

Page 22: ...ll not displayed it means either the transmitter is not available or it is faulty IMEI GSM IMEI GSM of a transmitter It is displayed automatically when configuring the local device When the device is remote it must be entered manually In the case of remote configuration via a satellite communication it is recommended to download the configuration from the cloud Work with the cloud configuration se...

Page 23: ...nt it is recommended to make a record according to the distance covered Historical records when parking If the object requires a long parking and at the same time it is necessary to periodically receive telemetry from it for example from the fuel sensor for drain you can use this option It is recommended to set an equal value Traffic restriction month bytes Setting up the limit of the terminating ...

Page 24: ...of points recording into memory is the time during which the coordinates are not recorded for any events Minimum number of satellites If the number of visible satellites is less than the specified value the coordinates are considered invalid and are not recorded Operating mode of the Receiver the device operates with two satellite systems GLONASS and GPS The user can select one of the systems or a...

Page 25: ...requency Input 1 8 For correct calculation of the frequency set the slider of the lower limit at the level of half the input signal amplitude discrete To connect digital sensors with two work position ON or OFF For example an alarm button closing the input to the supply voltage The HIGH active layer is used and it is recommended to set the upper limit at 6 10V The input status is transmitted in th...

Page 26: ...s flag can be processed by events for example dial specific numbers or to send an SMS with the specified text Repeated change to the active state drops the call if dialing of a number or a conversation started When using the NAVISET HF 1 handsfree this input function is performed by the button on the handsfree amplifier the effect of which is already provided in the configuration call by connectio...

Page 27: ...tor flag if the key touches the contactor and removes it if the key is not on the contactor If the checkbox is selected when the key touches the contractor an extraordinary data packet with a key code will be formed The key code is transmitted in all subsequent packets while the key is on the contactor Keep iButton code value until the ignition is switched off This function is available if the Con...

Page 28: ...can choose the port the sensor is connected to in the section SETUP OF CONNECTION TO THE DEVICE and click the Apply button Then you can change the settings of the sensor using the regular software via a virtual COM port created by the device Before starting operation via this port you need to close the Configurator program before opening this port using a third party software This mode allows you ...

Page 29: ...ce In the CLIENT mode the NAVISET device receives data from the external device and records them to the register specified by the user or the external device reads its values from this register In this mode the Naviset device network address is set in the ID field For each record the same ID is specified CAN BUS is the bus of a serial poll of the connected peripherals It is used in all types of mo...

Page 30: ...lue specified by the user After the settings are set and reboot is completed a few parameters will be displayed in the Value column 7 2 7 THE ENERGY SAVING PANEL There are three options for the automatic transition to the power saving mode 1 If the object stopped and has not changed its position over the time specified by the user 2 Is there is no external power supply the device goes into sleep m...

Page 31: ...ith the announcement of the next stop along the route in other direction the bus stops must be announced in reversed order therefore different voice phrases are used Creating a list of coordinates of geofence in two ways 1 During the movement of the vehicle along the route and recording the current coordinates the outer and inner radius of the geofence 2 In interactive mode noting the points on th...

Page 32: ... configuration of the device to the cloud service This function is very useful to remotely configure or to set up a large number of devices without a connection to a PC The function is available if the computer on which the program configurator is open has the Internet connection The Send the configuration to the cloud button works only when the device is directly connected to a PC and the identif...

Page 33: ...nts that can be interconnected built in the logical chains independently changing static parameters All the logic is based on three main recommended algorithms 1 The linear algorithm as soon as all conditions of the event are fulfilled the event is active the device consistently performs all actions If the event is still active the actions are repeatedly performed 2 The cyclic algorithm is similar...

Page 34: ...ue on the battery 0 4 5 Security state Logic Active Inactive Alarm It occurs with the active signal on input with function standard alarm output when the security mode is on Logic Active Inactive Keys on the contactor It occurs at the moment of reading electronic key code of the iButton or Proximity cards Logic Active Inactive Keys from memory It occurs if the iButton key is recorded in the memory...

Page 35: ...ter Description Taken values Operation Start events processing Perform the actions of any of the created events even if the conditions for this event are not fulfilled ATTENTION It may lead to an infinite cycle Number one of the existing events For the current one the specified number is 256 Send an extraordinary packet Record to buffer for transmission of extraordinary data packet Play a voice ph...

Page 36: ...witch SW1 see Table 3 to allocate the RS232 interface for this port To check if a video camera is connected properly click PREVIEW If within 10 seconds a video frame appears the camera is connected correctly if not check the connection of the connecting wires between the camera and the device DRIVER IDENTIFICATION A list of electronic keys that are responsible for the identification of the drivers...

Page 37: ...eck the box Run the fuel sensor s calibration wozard 9 FUEL SENSORSCOLEBRATION WIZARD The configurator allows you to make calibration of the fuel sensors connected to device in automatic and manual mode After Completion of wizard operation the user receives a calibration table which can be printed out saved in a file or in one of two built in calibration tables The built in calibration tables allo...

Page 38: ... In the table of values the sensor readings corresponding to the amount of fuel poured in the tank will appear Continue to pour fuel intill the tank is completely filled by pressing the Save button after each portions When filling the tank press the STOP and save the table into a file or one of the two calibration tables in the memory of the device Press the Clear button before starting the next c...

Page 39: ... in the calibration process will indicate how many liters have already been in the tank Specify the input that is connected to the fuel flow meter In the example in the picture the fuel flow meter is connected to the INPUT 2 Specify output for pump control In the example in the picture the fuel flow meter is connected to the INPUT 3 Specify the pause between the portions Specify the number of flow...