background image

• 

Important health and safety information 

When using this product, take the following precautions in order to avoid possible damages and 

legal consequences. Always follow all safety and operation manuals exactly and keep them for 

future reference. Observe all warnings in the operation manual and on the product. In order to 

avoid injuries, electrocution, fire and damages to the product, observe the following precautions: 

 

• Electric security 

This product is designed for operation with power supply via the USB port. Any other operation 

mode can be dangerous and may void the warranty claims for this product. This unit contains an 

internal back-up battery. 

 

NOTE: 

RECYCLE OR DISPOSE OF USED BATTERIES OR RECHARGEABLE BATTERIES IN 

ACCORDANCE WITH ALL APPLICABLE REGULATIONS AND THE INSTRUCTIONS INCLUDED 

WITH THE PRODUCT. 

 

 

 

 

 

 

 

 

• Precautions regarding direct sunlight

 

Make sure the unit is not exposed to very high humidity and temperatures. Never leave the unit, 

the battery or the rechargeable battery for an extended period in a vehicle or plate, where the 

temperature can increase to over 60°C (140°F), for example on the dashboard of a car, the 

window sill or behind a pane of glass, which is directly exposed to the sun or very strong UV 

light. Otherwise the unit or the vehicle may be damaged, and the battery or the rechargeable 

battery may overheat. 

 

• Damages requiring repairs 

Disconnect the unit from the AC supply in the following cases; also disconnect the rechargeable 

battery and contact an authorized repair man or your dealer. 

• 

Liquid or an object has entered the product. 

• 

The product has fallen down or was damaged. 

• 

There are visible signs of overheating. 

• When operated normally, the product does not function flawlessly. 

 

• Avoid using the unit directly after strong temperature changes. 

If the unit is exposed to strong temperature and humidity fluctuations, condensation can form in 

the unit. In order to avoid damage to the unit, please wait until the condensation has dried off 

before using the unit. 

 

 

NOTE: 

If you bring the unit from a cold to a warm environment, or vice versa, first let it get 

accustomed to the new temperature before turning it on. 

 

Summary of Contents for NL-82003P

Page 1: ...NL 82003P u blox NEO M8U multi GNSS UDR M8 serial receiver 0 5 m operation manual 62759 ...

Page 2: ...km h has to be completed The journey can be completed in normal road traffic with curves and acceleration periods During this travel the above mentioned sensors values are calibrated fully automatic During this time the receiver supplies the normal GNSS position data From the time of the successful sensor calibration the UDR position data is added to the GNSS position data in the NMEA 4 1 protocol...

Page 3: ...rechargeable battery for an extended period in a vehicle or plate where the temperature can increase to over 60 C 140 F for example on the dashboard of a car the window sill or behind a pane of glass which is directly exposed to the sun or very strong UV light Otherwise the unit or the vehicle may be damaged and the battery or the rechargeable battery may overheat Damages requiring repairs Disconn...

Page 4: ... navigation or route planner software Do not use another program that accesses this port at the same time 2 3 Calibration ride Check whether the receiver has a proper GNSS reception at the installation location As a Fix Mode 3D must be reached Drive with a car with good GNSS reception signals about 20 minutes During the journey you must reach speeds over 30 km h The sensors calibrate automatically...

Page 5: ...lso serves for updating the Assist GNSS data and other configuration switches as SBAS properties If the NMEA protocol is displayed in u center but you cannot find a receiver in the application software the connection problem is not with the receiver but with the selected software setting In this case the software manufacturer support center may be able to help you After starting the u center softw...

Page 6: ...ons available V RTCM 2 3 SDCM RUS I x x x x x x x x x II x x x x x x x x x III x x IV x x x x x x x x V x x x x x x x x VI x x x x x x x x x x VII x x x x x x x x x x VIII x x x x x x x IX x x x x x x x MSAS J GAGAN IND SNAS CHN GPS GNSS SBAS Galileo EU GPS USA GLONASS RUS BeiDou CHN QZSS J EGNOS EU WAAS USA expected to be available in 2017 please visit our website for updates Expected to be avail...

Page 7: ... 24 NL 82003P uses EGNOS as default In the configuration menu you can check these options For detailed information please use the documentation from u blox https www u blox com sites default files u center_UserGuide_ 28UBX 13005250 29 pdf ...

Page 8: ... takes 26 seconds under optimal reception conditions but under less favorable conditions it may take much longer e g in an urban environment or in a building where the GNSS reception is weaker AssistNow sends the data directly to the GNSS receiver enabling a quick calculation of the position The offline service provides support data which are valid up to 35 days The user can profit for longer peri...

Page 9: ...ircumstances because it can otherwise be completely and irreparably destroyed Return the receiver to our support center mentioning water damage The support center will disassemble the receiver dry it and check its functionality The Navilock repair center tries to be as obliging as possible so please tell us the real reason for the defect During the error analysis we can generally detect if the cau...

Page 10: ...GPS time Speed 0 1m s Date WGS 84 Protocol NMEA 0183 V4 1 GGA GSA GSV RMC VTG Detection rates Cold start 26 s average Hot start 1 s average Re Acquisition 1 s average Update rate 20 Hz Dynamic prerequisites Acceleration limit smaller than 4 g Height limit 50000 m Speed limit 500 m s Performance Power supply 5 48 V DC via connection cable M8 RS232 A62875 5 V DC via connection cable M8 USB A62970 Co...

Page 11: ...on fee for a telephone call to Germany Berlin in accordance with the connection fee overview of your telephone service provider Callers from Germany who subscribed to a national telephone flat rate service and can call nation wide fixed telephone numbers free of charge can call us without incurring additional charges You can also find current product information on our homepage www navilock com 13...

Page 12: ...rresponding collection sites The separate collection and meaningful re usage of electronic waste helps to deal with natural resources more economically In addition re using electronic waste contributes to the preservation of the environment and human health Additional information regarding the disposal of electric and electronic devices their re usage and the collection sites can be found at your ...

Reviews: