STEP 3 After Installing
Opening All the Valves
>
Gas Valve
Closed
Open
Power ON
Adjust the Water Temperature
View Basic Information
Resetting the Water Heater
To turn the water heater on, press the Power
button ( ).
When the power is on for the first time, you
must complete the start-up wizard. The
temperature will appear on the front panel
display after then when the power is on.
Press the Up button ( ) or the Down button ( )
until the desired temperature appears on the
display. You can adjust the temperature while
the display is flashing. Once the display stops
flashing, the temperature setting is stored.
To access to view the water heater’s operating
conditions, configure the DHW temperature, or
review the error history, press the Menu button (
).
Note
If resetting does not solve the problem, refer to the troubleshooting
section of the User’s Information Manual or contact the service center.
If an error message appears, you can try resetting
the water heater to resolve the problem. To reset
the water heater, press the Back button ( ).
1
Open
Closed
2
3
4
5
Shut off the manual gas valve.
Open a hot water faucet to turn
on the unit.
Shut off the hot water faucet.
Remove the 4 screws of the front
cover assembly.
Loosen a screw two or three turns and
connect a manometer to the pressure
port.
6
Open
7
8
NG: 3.5”–10.5” WC
LP: 8.0”–13.0” WC
Recommended
Gas Pressure Settings:
Gas supply
Adjust the inlet gas pressure
with gas regulator.
Re-open the
manual gas valve.
Open several fixtures that have
high flow rates.
Check the inlet gas pressure reading on the manometer.
CAUTION
The Navien water heater cannot operate properly without sufficient inlet gas pressure and volume. The instructions on how to check the inlet gas pressure are stated above.
THIS IS ONLY TO BE DONE BY A
LICENSED PROFESSIONAL.
If not,
Navien, Inc.
20 Goodyear, Irvine, CA 92618
Tel: 1-800-519-8794, Fax: 1-949-420-0430
Installing the Front Cover
>
Ensure Maximum Water Flow
>
After using the water heater for the first 10 minutes, please stop using it and clean the
cold water filter and recirculation water filter of any trapped debris.
Final Check
>
A trial run should be performed in accordance with the Installation checklist listed in
the Installation & Operation Manual.
Operating the Water Heater
>
Measuring the Inlet Gas Pressure
>