97
Operating the Boiler
11.4 Adjusting the System Temperatures
In normal operation mode, space heating temperature for each zone can be set depending on the settings in the
following table.
Settings
Space heating settings
Zone Priority Settings
Zone Settings
Pump 1 Settings
Disable
N/A
N/A
Space heating temperature settings
Enable
Zone Pump System
DHW Pump
Space heating temperature settings
for Zone 2 and Zone 3 (“Pump 1
Settings” is set to “DHW Pump”.)
Enable
Zone Pump System
Zone1 Pump
Space heating temperature settings
for Zone 1, Zone 2 and Zone 3
Enable
Zone Valve System
DHW Pump (Default) Space heating temperature settings
for Zone 1, Zone 2 and Zone 3
For more information on the zone settings and zone priority settings, refer to “11.5.2 Setting the Space Heating
2. Press the Command dial (
) to select the space
heating temperature. The highlighted section
will flash.
3. Rotate the Command dial (
) to the right or
left to increase or decrease the temperature.
4. Press the Command dial (
) to confirm the
new temperature.
5. Press the Back button (
) to return to normal
operation mode, or rotate the Command dial
(
) to adjust other operation conditions.
You can adjust the temperature while the
highlighted section is flashing. Once the flashing
stops, the current temperature setting is stored.
11.4.1 Adjusting the Space Heating
Temperature (When “3. Zone Priority
Setting” is disabled)
To adjust the heating temperature:
1. In normal operation mode, rotate the Command
dial (
). The space heating temperature ( ) is
highlighted on the screen.