41
Condition/Problem
Things to Check
Solution
No display/partial display/
unit will not turn on
Check electrical (wall)
outlet
Make sure unit is plugged into a functioning wall outlet.
Check connection at front
of unit
Connection should be secure and undamaged. Replace
adapter or connection at unit if either are damaged.
Check data cable integrity
All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Check console display for
damage
Check for visual sign that console display is cracked or other
wise damaged. Replace Console if damaged.
Console Display
,I&RQVROHRQO\KDVSDUWLDOGLVSOD\DQGDOOFRQQHFWLRQVDUH¿QH
replace the Console.
If the above steps do not resolve the problem, contact Cus
tomer Care for further assistance.
Unit operates but Contact
HR not displayed
HR cable connection at
Console
Be sure cable is connected securely to Console.
+5FDEOHER[FRQQHFWLRQ
Be sure cables from handlebars and cable to Console are
secure and undamaged.
Sensor grip
Be sure hands are centered on HR sensors. Hands must be
kept still with relatively equal pressure applied to each side.
Dry or calloused hands
6HQVRUVPD\KDYHGLI¿FXOW\ZLWKGULHGRXWRUFDOORXVHGKDQGV
A conductive electrode cream (heart rate cream) can help
make better conduct. These are available on the web or at
PHGLFDORUVRPHODUJHU¿WQHVVVWRUHV
Static Handlebar
If tests reveal no other issues, Static Handlebar should be
replaced.
Unit operates but
Telemetric HR not
displayed
Chest Strap (optional)
Strap should be “POLAR
®
” compatible and uncoded. Make
sure strap is directly against skin and contact area is wet.
Chest Strap Batteries
If strap has replaceable batteries, install new batteries.
&KHFN8VHU3UR¿OH
6HOHFWWKH(GLW8VHU3UR¿OHRSWLRQIRUWKH8VHU3UR¿OH*RWR
the WIRELESS HR setting and make sure that the current
value is set to ON.
Interference
7U\PRYLQJXQLWDZD\IURPVRXUFHVRILQWHUIHUHQFH790LFUR
wave, etc).
Replace Chest Strap
If interference is eliminated and HR does not function, replace
strap.
Replace Console
If HR still does not function, replace Console.
Unit operates but
Telemetric HR displayed
incorrectly
Interference
Make sure that the HR receiver is not blocked by a personal
electronic device in the left side of the media tray.
No speed/RPM reading,
Console displays “Please
Pedal” error code
Check data cable integrity
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
TROUBLESHOOTING
Summary of Contents for R618
Page 1: ...ASSEMBLY MANUAL OWNER S MANUAL R618 ...
Page 11: ...11 3 Attach the Seat Pivot Shrouds and Seat Back to the Seat Frame Assembly 6 C 6mm I I 3 3 ...
Page 13: ...13 5 Attach Seat Adjustment Handle to Frame Assembly 12 N 6 mm E F X2 ...
Page 14: ...14 6 Attach Seat Bottom to Seat Frame Assembly 4 H J D 2 X4 ...
Page 44: ...44 ...
Page 46: ...Nautilus RZÀH Schwinn 8QLYHUVDO 8010872 080118 H EN ...