5.
LOCATION, SAFETY, OPERATION, BOTTLE FILLING
LOCATION
Keep unit away from flammable items. Do not smoke while petrol tank is open and while unit is in
operation.
•
Compressor should be parallel to the floor. Maximum allowable inclination is 5 degrees to ensure effective
lubrication and operation.
•
An air conditioner is required if the operation temperature exceeds 40 °C
•
Position the machine at a minimum distance of 1m from surrounding walls and 1.5 m from ceiling in order not to
compromise the proper operation and cooling of the compressor.
•
Do not operate unit in vicinity of open fire.
•
Ensure adequate ventilation.
•
Air must be free from exhaust fumes and hazardous vapors (e.g. smoke, solvent vapors, high concentration of
dust, etc.)
•
If possible, install unit for the compressor fan to be able to get fresh air.
•
Ensure adequate exhaust air opening is provided.
•
When operating in location where natural ventilation is not ensured, measures must be taken to provide artificial
ventilation.
SAFETY
•
The compressor room should be kept tidy, the floor area clear of obstacles and doorways unobstructed.
•
Eye protection should be worn when carrying out any mechanical operation, especially where rotating tools and
compressed air are involved.
•
Ear defenders should be used when operating compressed air tools, releasing compressed air, working near
compressors or whenever the ambient noise level exceeds 90 decibels (dBa)
•
Shoes or boots with built in toe protection should be worn whilst handling heavy items.
•
Barrier creams should be used when using oils, greases, solvents, adhesives, cleaning agents and chemicals.
Rashes and dermatitis are not uncommon when working with these products.
•
Diameter of copper core wire should not be less than 2.5cm
2
, length not shorter than 10 meters for single phase
power extension cord. (Wire connection not following the standards will cause an increase in operation
temperature due to higher electrical resistance, increasing the risk of equipment failure)