28
CLEAN CHEMICAL FEED FILTER & FOOT VALVE:
(If so equipped)
Part of the optional Auto Fill & Chemical Feed system, the Filter & Foot Valve is on the end of the chemical
feed hose that is placed in the chemical jug as part of the chemical feed system. Regularly examine the filter
and clean as needed.
To test the Foot Valve:
•
Remove the Filter & Foot Valve from the end of the chemical feed hose and rinse in fresh water.
•
Blow through the valve from the filter side of the barb.
o
If the Foot Valve is functioning, air should move freely from the filter side, but will not flow from
the barb side of the filter.
o
If valve is not functional, clean or replace as needed.
Heavy chemical build-up can be removed with a mild acid rinse and/or the use of a brush and compressed
air.
CLEAN VACUUM SHUTOFF ASSEMBLY SCREEN:
Inside the recovery tank, on top of the stand pipe, is the Vacuum Shutoff Assembly. It functions to prevent
debris and water from being sucked into the vacuum motors. Operating the Nautilus Extreme MXE-500
without the Vacuum Shutoff Assembly or with a poorly maintained assembly will greatly decrease the life of
the vacuum motors and will void the warranty.
If debris builds up on this filter, it will reduce the vacuum air flow and may cause a significant decrease in the
rate of water recovery. If debris prevents the float from moving or seating against the Filter Cap Assembly, it
may not stop the airflow when the tank fill with water, and the water will be sucked into the vacuums and
blown out the exhaust.
Use defoamer to prevent foam or moisture from entering vacuums (See Page 15).
To clean:
•
Do not pull up on top of cap.
Carefully pull up from the bottom of filter cap assembly to pull the
assembly off of the stand pipe. Then pull float off of riser pipe.
•
Pull fibers and lint off and rinse filter cap assembly and float with clean water.
•
Place the float back on the riser pipe then push the filter cap assembly back onto the stand pipe and
replace the recovery tank lid.
Flow Direction
Flow Direction
Filter & Foot Valve
PDE100-11P
Chemical Feed Hose
Vacuum Shutoff
Assembly
Filter Cap Assembly
Vacuum Shutoff Float
Summary of Contents for Extreme MXE-500
Page 1: ...1 LMANN21 REVISED 01 29 2015 MXE 500 Operating Manual EXTREME...
Page 38: ...38 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740...
Page 40: ...40 Pump Out Pump PARTS ASSEMBLY...
Page 41: ...41 1 2 10 11 4 3 5 4 3 7 6 8 9 8 9 8 9 8 9 39 12 2...
Page 48: ...48 2 39 1 72 73 73 67 9 30 31 82 83 2 83 82 84 INSIDE SOLUTION TANK BOTTOM VIEW SOLUTION TANK...
Page 51: ...51 92 91 95 94 112 13 14 14A 104 105 1 39 OPTIONAL PUMP OUT CONNECTIONS...
Page 52: ...52 35 36 79 78 36 79 34 39 123 124 125 2 1 128 32 34 126 39 127...