Summary of Contents for NA-D7200

Page 1: ...0...

Page 2: ...them through the innovative designs of our products We strive to achieve a high level of user friendliness by allowing stress free installation and easy operation of all important functions of the ca...

Page 3: ...To return your product for service please contact your regional authorized service centre s Please note that this warranty only applies when the product is purchased in the territory where the service...

Page 4: ...r main o ring 4 O ring remover 5 CR2032 battery for moisture alarm 6 Lubricant 7 Set of Allen keys 8 M10 plastic plug removal tool for removal of M10 plastic insert Spare silicone rubber o ring Lubric...

Page 5: ...g if the port is installed as this may lead to a pressure difference between the atmosphere and inside the housing 6 Care must be taken when opening the housing as pressure may build up inside the hou...

Page 6: ...pecifications 6 Identification of Parts 7 Opening and Closing the Housing 11 Preparation of the Housing 12 Installing the Camera 17 Mounting the Port 19 Changing the Viewfinder 21 Care and Maintenance...

Page 7: ...ating 100 metres Features Moisture alarm Blinking LED and audible alarm Viewfinder 0 66X viewfinder TTL capability Nikonos 5 pin bulkheads optional 2 optical bulkheads utilising on camera pop up flash...

Page 8: ...7 1 On Off control knob 4 Optical bulkhead for strobe connections x 2 2 Grip handle x 2 5 Port alignment index 3 Port lock release lever 1 3 2 5 4 2...

Page 9: ...mmand dial 13 M14 accessory port 8 Movie record lever 14 M10 plastic plug M5 on top M10 on housing 9 AF ON lever 15 Shutter release lever 10 Exposure compensation lever 16 Sub command dial 11 Info lev...

Page 10: ...ector lever 22 Housing lock L 31 Multi selector 23 Housing lock safety button L 32 Up selection button 24 Playback zoom in Image quality button 33 Left selection button 25 i button 34 OK button 26 Moi...

Page 11: ...flash compensation button 46 Flash Off lever 40 Zoom focus gear disengagement lever 47 M10 plastic plug M5 on top M10 on housing 41 Zoom focus knob 48 Playback zoom out ISO sensitivity lever 42 Lens...

Page 12: ...e sure there is nothing caught between the closing surfaces of the two halves of the housing 2 The housing can be opened and closed by operating the two housing locks when opening press the safety but...

Page 13: ...e the main O ring into the groove by gently pushing it first at the corners then the whole perimeter 4 Optional If necessary spacers 25011 can be used to increase space between the grip handles and th...

Page 14: ...bulkhead through the threaded hole vi Slide the accessory shoe plug of the housing into the accessory shoe of the camera iv Tighten the 5 pin bulkhead with a spanner v Connect the 5 pin bulkhead to t...

Page 15: ...n blue for five seconds indicating the battery is normal Then it goes into flashing blue light standby mode 3 Test the alarm by contacting the two wires near the bottom of the housing with a damped co...

Page 16: ...m is ready for vacuum indication whenever a vacuum is detected Flashing Red light with beeping sound Moisture is detected Flashing Yellow light Some vacuum is detected target vacuum level is not reach...

Page 17: ...by turning the vacuum release ring anti clockwise 2 Remove the port and lens from the housing and camera 3 Press the BLUE button once to reset the system The LED light will turn blue for five seconds...

Page 18: ...the housing to the open position 2 Remove the camera saddle from the housing 4 Align the pin on the saddle with the opening in the bottom of the camera as indicated in the diagram 3 Pull the sliding...

Page 19: ...amera into place by turning the locking lever to the lock position 9 Confirm that all the controls of the housing are correctly engaged 10 For removal of the camera from the housing reverse the above...

Page 20: ...ent of ports of other manufacturers 2 Turn the port locking lever to the release position as shown 1 Push the safety button of the port locking lever downwards 3 Lift housing cap 4 Pull down the Zoom...

Page 21: ...m that the green line on the safety button of the port locking lever is visible 10 To remove the port from the housing simply turn the port locking lever to the outward position and gently pull it out...

Page 22: ...d re installed by following the simple steps described below To remove the viewfinder To re install the viewfinder 2 Gently push the viewfinder from the inside of the housing 3 Push the viewfinder fro...

Page 23: ...ain O ring in the front part of the housing removed from its groove with the O ring remover and inspected for damage Also check that the O ring retains its original circular shape never stretch the O...

Page 24: ...23...