29
C
ARE AND
M
AINTENANCE
•
Soak the housing system in fresh water after each salt water use, during which all control
buttons/knobs should be operated a few times to avoid the accumulation of salt residue; wipe the
housing with a towel before opening.
•
Carefully press the housing lock safety button for a few times to avoid the accumulation of salt
residue.
•
After each day of diving, it is advisable to have the main O-ring in the front part of the housing
removed from its groove with the O-ring remover and inspected for damage. Also check that the O-
ring retains its original circular shape; never stretch the O-ring excessively or remove it with a sharp
object. The O-ring groove should be cleaned to ensure it is free from any salt deposit or foreign
material; lightly coat the O-ring with the provided lubricant before reinstalling it in the groove. A
damaged O-ring should be discarded immediately and replaced only with one that is provided by
NAUTICAM.
•
Replace the main O-ring annually. It is recommended that you ship the housing to our distributor for
a complete overhaul every year or after every 200 dives.