background image

 

PRECAUTIONS 

 The following procedures are advised to be followed: 

 

Soak  housing  along  with  the  EMWL  in  fresh  water  a  few 
minutes  after  each  time,  the  lens  port  surface  and  body 
should be rinsed thoroughly in fresh water. 

 

Dry and clean the glass surface of the EMWL with the cloth 
provided. 

 

Cover the lens with the provided cover when not in use. 

 

DO NOT use any kind of abrasive solutions to clean the glass 
surfaces. 

 

Do not store the EMWL in an environment of high humidity, 
extreme temperatures, and direct sunlight.  

 

Do not point the housing set up and lens directly at the sun. 

 

Keep out of reach of children, failure to do so could result in 
injury. 

 

Defective products should be shipped to our distributors for 
service,  unauthorized  disassembling  and/or  modifications 
could result in malfunction or leakage. 

 

Never  jump  in  the  water  holding  your  housing  and  lens. 
Always have the housing set up handed to you. 

 

 

Use a reference to gauge the distance between the subject 
and  the  front  element  to  avoid  accidentally  scratch  the 
EMWL surface.

 

 

Release air bubbles or sand trapped in between the lenses 
after changing the lens modules.  

 

 

 

C

ARE AND 

M

AINTENANCE

 

 

Store the housing and EMWL in a robust, shock-proof container 
during  transportation;  avoid  transporting  the  lens  with  the 
housing sealed.  

 

When  travelling  by  air,  it  is  important  that  the  housing  is  not 
sealed. Either remove the O-rings, the port, or leave the back of 
the housing open.  

 

Change lens port in a dry, calm, sheltered area. 

 

After opening the housing or unmounting EMWL, wipe off water 
on  the  O-ring  with  a  microfiber  towel.  Avoid  droplets  into  the 
lens port.   

 

Examine  the  O-ring  and  sealing  surfaces  carefully  before 
closing the housing.  

 

Conduct  a  vacuum  test  30~40  mins  before  the  next  dive  to 
make sure the system is intact. Make sure the vacuum valve 
cap is on.   

 

A  damaged  O-ring  should  be  discarded  immediately  and 
replaced only with one that is provided by NAUTICAM.     

 

Replace the main O-ring annually.

 

 

 

 

 

 

 

Summary of Contents for 87301

Page 1: ...otographers and fulfill them through the innovative designs of our products We strive to achieve a high level of user friendliness by allowing stress free installation and easy operation of all import...

Page 2: ...cables carry a year warranty This warranty only applies to products purchased from authorized NAUTICAM dealers and does not extend beyond the original retail purchaser To return your product for serv...

Page 3: ...g 616g 410g Body construction Hard anodized aluminum alloy Lens construction 6 elements in 3 groups 6 elements in 3 groups 6 elements in 3 groups Lens coatings Inside anti reflective coating Mount sys...

Page 4: ...Lens Outer diameter x Length 62 mm x 97 0 mm 62 mm x 88 5 mm 62 mm x 123 2 mm Weight air uw 378g 260g 218g 130g 510g 290g Body construction Hard anodized aluminum alloy Lens construction 9 elements i...

Page 5: ...e housing set up handed to you Use a reference to gauge the distance between the subject and the front element to avoid accidentally scratch the EMWL surface Release air bubbles or sand trapped in bet...

Page 6: ...Unit 1 o 87211 EMWL 150mm Relay Lens o 87221 EMWL 60 Objective o 87222 EMWL 100 Objective o 87223 EMWL 130 Objective 87302 package o 87202 EMWL Focusing Unit 2 o 87211 EMWL 150mm Relay Lens o 87221 EM...

Page 7: ...L 100 Objective Lens 87223 EMWL 130 Objective Lens 87211 EMWL 150mm Relay Lens 87201 EMWL Focusing Unit 1 87202 EMWL Focusing Unit 2 87203 EMWL Focusing Unit 3 Lens Release Button Alignment I Index Al...

Page 8: ...Connecting the relay lens and a focusing unit 1 Align the O index mark on the objective lens with the I mark on the relay lens focusing unit 2 Turn the lens clockwise until the O mark on the lens ali...

Page 9: ...EPARATION OF THE REPARATION OF THE EMWL EMWL EMWL EMWL MODULES MODULES MODULES MODULES 3 Press the RED lens release button to reverse the steps and unmount the lenses 4 Turn the bubble release ring to...

Page 10: ...to Bayonet Converter 83250 2 Align the I mark on the EMWL focusing unit with the I mark on the converter and then push it in 1 Install the M67 to bayonet converter 83250 on a recommended lens port bef...

Page 11: ...the lens aligns with the WHITE dot on the converter and a click sound is heard 4 To unmount the lens from the port press and hold the RED lens release button on the M67 to bayonet converter and then t...

Page 12: ...e Lens 87221 features three focusing distance ranges which are 1 55mm 2 55 25mm 3 25 15mm Please adjust the lens to align with corresponding indication mark for the desired working distance ABOUT THE...

Page 13: ...t Rubber Lens Cap for 87221 87507 Padded Travel Bag for 87301 2 3 87508 Padded Travel Bag for 87201 2 3 87509 Padded Travel Bag for 87221 2 87510 Padded Travel Bag for 87223 87512 Shade for 130 Object...

Page 14: ...D 18702 Macro port 87 N85 Micro 4 3 M 4 3 mount Olympus M Zuiko Digital ED 60mm f 2 8 Macro 36163 Macro port 65 EMWL FOCUSING UNIT 2 87302 N120 Canon EF mount RF mount with Canon mount adaptor EF to E...

Reviews: