XR6/XR3 Operations and Maintenance Manual
Operating the transmitter
Issue 3.1 2013-03-14
Page 2-25
To view the
Calibrate Analog Meter
page, select
Settings
from the
MAINMENU
page. Next, select
Hardware Settings
,
Calibration Settings
from the
, then select
Calibrate Analog Meter
from the Calibration Settings menu.
Figure 2.19: Calibrate Analog Meter page
To recalibrate the analog meter, perform the following steps (see
):
1. Use the
Up
and
Down
buttons to select
Full-Scale Meter Deflection
. Press the
Edit
button,
then press the
Up
and
Down
buttons, to adjust the meter until it reads exactly full scale (full
deflection to the right). Press the
Save
button to save your calibration. (Pressing the
Cancel
button discards your changes.)
2. Use the
Up
and
Down
buttons to select
Full-Scale Meter Reading
. Press the
Edit
button,
then press the
Up
and
Down
buttons, to adjust the digital value until it reads exactly the
same as the full-scale meter indication. Press the
Save
button to save your calibration.
3. Use the
Up
and
Down
buttons to select
Half-Scale Meter Reading
. Press the
Edit
button,
then press the
Up
and
Down
buttons to adjust the digital value until it reads exactly the same
as the pointer. Press the
Save
button to save your calibration.
Calibrating B+ thresholds and switching points
You can recalibrate the XR6/XR3’s high and low B+ voltage thresholds, if necessary, using the
Calibrate B+ Thresholds and Switching Points
page. You can also determine the points at which
the XR6/XR3 B+ voltage switches between levels 0 (low), 2 (medium) and 3 (high) for 3-phase XR6;
levels 0 (low) and 3 (high) for 3-phase XR3; or levels 0 through 3 for 1-phase XR6/XR3.
Notes:
The transmitter is calibrated at the factory. Do not change calibration settings unless absolutely
required.
10:18 0.00kW M-1 B+1 PM:A Man Ex:A Man
Full-Scale Meter Deflection: 217
Full-Scale Meter Reading: 9.00 kW
Half-Scale Meter Reading: 2.26 kW
Use the arrow keys to select value to
view. Ensure that all meter readings
match. Press EDIT to make changes.
Edit
Back
10:18 0.00kW M-1 B+1 PM:A Man Ex:A Man
Full-Scale Meter Deflection: 217
Full-Scale Meter Reading: 9.00 kW
Half-Scale Meter Reading: 2.26 kW
Use the arrow keys to select value to
view. Ensure that all meter readings
match. Press EDIT to make changes.
Edit
Back
Summary of Contents for XR6
Page 2: ......
Page 4: ......
Page 10: ...XR6 XR3 Operations and Maintenance Manual Page x Issue 3 1 2013 03 14...
Page 18: ...XR6 XR3 OPERATIONS AND MAINTENANCE MANUAL PAGE XVIII VERSION 3 1 2013 03 14...
Page 65: ...XR6 XR3 Operations and Maintenance Manual Using the event log Page 3 8 Issue 3 1 2013 03 14...
Page 71: ...XR6 XR3 Operations and Maintenance Manual Routine maintenance Page 4 6 Issue 3 1 2013 03 14...
Page 82: ......