VS300 Operations and Maintenance Manual
Operating the transmitter
Page 2-162
Issue 8.0 2016-03-01
Ramp-Up Speed Setting
From the front panel UI, you can set the transmitter’s ramp-up speed. This setting establishes the
time it takes the transmitter to ramp up from 0 W to full power. At 100%, ramp-up speed is
approximately seven seconds. For a setting of 50%, ramp-up would be approximately 14 seconds. For
a setting of 25%, ramp-up would be approximately 28 seconds. In multi-transmitter systems that are
on a common generator or power grid, adjusting the ramp-up speed can be used to reduce the
transient load on the source during an ac power recovery (i.e., after a power failure or changeover to a
generator).
To view the
Ramp-up Speed
screen, select
User Settings -> Ramp-up Speed
from the
Main Menu
).
Figure 2.138: Ramp-up Speed Screen
Use the up and down buttons to select a ramp-up speed between 1 and 100% (in 1% increments),
noting 100% represents approximately seven seconds (0 W to full power). The default setting is 100%
(approximately Press the accept (checkmark) button to save the change. Press
X
to abort the reset and
return to the previous menu.
Note:
Configuration of the Ramp-Up Speed setting is only available using the front panel UI.