Using the parameters from the
Outputs
), you can configure up to 16 remote
outputs that indicate either the presence of various alarms or the status of operator controlled
circuits.
Nautel sets remote output defaults prior to shipping. See the
NX50 Pre-installation Manual
for details.
If necessary, re-configure the remote outputs as follows:
Figure 2.94: Remote I/O - Output Parameters
1. On the left side of the page, select the desired remote output (1 through 16) from the list.
Note: you can configure remote outputs 1 through 16 for one of a variety of monitoring
outputs.
2. On the right side of the page, assign a name to the remote output by pressing
Channel
and
selecting one of the following options:
•
Not Assigned
- No alarm or status parameter is monitored.
•
Remote Enabled
- Active logic level indicates the transmitter’s remote control is enabled.
Inactive logic level indicates the transmitter is in local control only.
•
RF On/Off
- Active logic level indicates the transmitter’s RF power stage is on (enabled).
Inactive logic level indicates the transmitter’s RF power stage is off.
•
Active Exciter
- Active logic level indicates that exciter A is active. Inactive logic level indi-
cates that exciter B is active.
Exit page
Outputs tab
Current
logic level
Summary of Contents for NX50
Page 2: ......
Page 4: ......
Page 8: ...NX50 Operations and Maintenance Manual Page viii Issue 3 3 2016 02 08...
Page 156: ...NX50 Operations and Maintenance Manual Routine maintenance Page 3 6 Issue 3 3 2016 02 08...
Page 162: ...NX50 Operations and Maintenance Manual Non standard maintenance Page 4 6 Issue 3 3 2016 02 08...
Page 165: ......