NX5 PRE-INSTALLATION MANUAL
PLANNING CONTROL/MONITOR CONNECTIONS
PAGE 1.8.4
VERSION 0.1 2015-08-01
Option 1 - Internal Dc Supply
If you plan to use the transmitter's internal 15 V supply as the source for the remote inputs (1 through
10), the type of connections to the control/interface PWB (A4) are shown in
When the remote input is configured for ‘falling edge’ or ‘active low’ logic, a logic low command
(current-sink-to-ground) must be applied to the appropriate remote input (1 through 10). To avoid a
ground loop, obtain the ground from the appropriate pin of J6A (see
). When
the remote input is configured for ‘rising edge’ or ‘active high’ logic, a logic high command (open
circuit) must be applied to the appropriate remote input (1 through 10).
Figure 1.8.1: Remote Input Connection - Internal Dc Supply Selected
The momentary switch should be located between a ground source on the control/interface PWB and
the remote input.
E1
1
GND
+15 V INPUT
REMOTE INPUT (01 TO 10)
INT
J6A-9/21
DC SUPPLY
INTERFACE
CONTROL/
2
J6A-11/23
3
+15V
PWB
S2120500 V1
CONFIGURED FOR INTERNAL
REMOTE SELECTION CIRCUITRY
NOTE
: The selected configuration is
detemined by a single jumper setting (E1)
on the control/interface PWB and applies
to all remote inputs (1 through 10). They
cannot be configured separately.
Summary of Contents for NX5 AM
Page 2: ......
Page 4: ......
Page 8: ...NX5 PRE INSTALLATION MANUAL TABLE OF CONTENTS PAGE 1 VIII VERSION 0 1 2015 08 01 ...
Page 10: ...NX5 PRE INSTALLATION MANUAL PAGE 1 X VERSION 0 1 2015 08 01 ...
Page 22: ...NX5 PRE INSTALLATION MANUAL PAGE 1 XXII VERSION 0 1 2015 08 01 ...
Page 79: ...NX5 PRE INSTALLATION MANUAL PARTS AND TOOLS PAGE 1 9 4 VERSION 0 1 2015 08 01 ...
Page 85: ...NX5 PRE INSTALLATION MANUAL PRE INSTALLATION ASSISTANCE PAGE 1 10 6 VERSION 0 1 2015 08 01 ...
Page 88: ......