![Nautel NX5 AM Operation & Maintenance Manual Download Page 176](http://html1.mh-extra.com/html/nautel/nx5-am/nx5-am_operation-and-maintenance-manual_711218176.webp)
NX5 OPERATION & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
PAGE 3.2.156
VERSION 0.1 2015-08-01
SWR Threshold Adjustment
You can adjust various SWR threshold levels using the remote AUI (see
Adjusting SWR Thresholds - Using
) or the local front panel UI (see
Adjusting RF Symmetry - Using the Front Panel UI
change a setting on the front panel UI, it will also be reflected on the remote AUI, and vice versa.
Adjusting SWR Thresholds - Using the Remote AUI
The remote AUI’s
SWR Thresholds
) displays the threshold values for
Peak
Reflected Limit
,
RMS Reflected Limit
,
Peak RF Current Limit
,
Peak Reflected Scale
and
Fast SWR
Shutback
. The peak reflected scale value has an associated calibration routine, which is initiated using
the
Start
button. Value changes and calibrations are not typically required.
Figure 3.2.142: Factory Settings - SWR Thresholds Page
WARNING!
Factory settings are established at Nautel and should not require
adjustment. These settings affect critical system protections. Making changes to
these settings may void your warranty. Contact Nautel before making changes.
For future reference, record a parameter value before and after making a change.
Summary of Contents for NX5 AM
Page 2: ......
Page 4: ......
Page 8: ...NX5 OPERATION MAINTENANCE MANUAL PAGE 3 VIII VERSION 0 1 2015 08 01 ...
Page 216: ...NX5 OPERATION MAINTENANCE MANUAL ROUTINE MAINTENANCE PAGE 3 3 12 VERSION 0 1 2015 08 01 ...
Page 219: ......