NX5 OPERATION & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
VERSION 0.1 2015-08-01
PAGE 3.2.151
B+ Voltage Calibration
You can calibrate the B+ voltage and adjust the B+ limit setpoint using the remote AUI (see
B+ Voltage - Using the Remote AUI
) or the local front panel UI (see
Calibrating Audio Inputs - Using the
). If you change a setting on the front panel UI, it will also be reflected on the remote AUI,
and vice versa.
Calibrating B+ Voltage - Using the Remote AUI
The remote AUI’s
B+ Calibration
) displays the B+ Limit Setpoint (high voltage
alarm level; nominally 420 V), the measured B+ levels, and a B+ Calibration Value field. The calibration
field allows you to enter a measured B+ voltage to calibrate the B+ based on an externally measured
B+ level. Save changes to the B+ Limit Setpoint value or the B+ Calibration Value by clicking the
appropriate
Apply
button.
Figure 3.2.135: Factory Settings - B+ Calibration Page
WARNING!
Factory settings are established at Nautel and should not require
adjustment. These settings affect critical system protections. Making changes to
these settings may void your warranty. Contact Nautel before making changes.
For future reference, record a parameter value before and after making a change.