GV60 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
PAGE 4.1.42
VERSION 1.0 2018-01-01
Table 4.1.3: Other Power Supply LED States
Operating with Defective or Missing Power Supply or LVPS Modules
You can operate the transmitter - at normal desired power level - with one defective or missing LVPS
module, assuming the transmitter was using dual LVPS modules. To replace an LVPS module, go to
“LVPS / Power Supply Module Replacement” on page 4.1.50
You can operate the transmitter - at a reduced output power level - with multiple defective or missing
power supply module(s) (see
). To replace a power supply module, go to
“LVPS / Power Supply Module Replacement” on page 4.1.50
Condition
Power Supply LED State
AC OK
(green)
DC OK
(green)
SERVICE
(amber)
FAULT
(red)
OK
On
On
Off
Off
Thermal alarm (5 degrees before shutdown)
On
On
On
Off
Thermal shutdown
On
Off
On
On
Defective fan, blown ac fuse, boost stage failure or over
voltage latched shutdown
On
Off
Off
On
Ac present, but not within limits
Blinks
Off
Off
Off
Ac not present
Off
Off
Off
Off
Non-catastrophic internal failure
On
On
Off
On
Standby
On
Off
Off
Off
Service Request (PMBus mode)
On
On
Blinks
Off
Communications Fault
On
On
Off
Blinks
Summary of Contents for GV60
Page 2: ......
Page 4: ......
Page 8: ...GV60 TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 1 0 2018 01 01 ...
Page 102: ...GV60 TROUBLESHOOTING MANUAL PARTS LISTS PAGE 4 2 12 VERSION 1 0 2018 01 01 ...
Page 463: ...VERSION 1 0 2018 01 01 MD 17 Figure MD 17 NAPA31C Power Amplifier PWB Q1 ...
Page 475: ...GV60 TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 1 0 2018 01 01 ...
Page 476: ......