GV5/GV3.5 OPERATIONS & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
VERSION 0.2 2014-07-23
PAGE 3.2.41
Available Instrument Panels
Spectrum Analyzer
. The carrier level is normalized to its unmodulated carrier level at 0 dB. The graph
center is always at the carrier frequency, as defined by the active preset’s Frequency value
.
Masks are shown based on transmission mode and are defined by the latest versions of the following
standards:
IBOC: NRSC-5
European Standard: ETSI EN 302 018-2
FCC CFR 47, Part 73.317 and IC BETS-6e
NOTE
: While very accurate, the spectrum analyzer may display artifacts (spurs) as some operating
carrier frequencies that are a function of the analyzer and are not actually present on the output of the
transmitter. If these spurious emissions are observed on the spectrum analyzer, Nautel recommends
that a calibrated, external spectrum analyzer be used to verify the presence of spurs.
Click or touch on the panel to display a cursor in the approximate area. The cursor position (frequency
and amplitude) is noted in the upper, right-hand corner of the panel. Select other areas of this
instrument panel to provide a coarse adjustment of the cursor position.
Figure 3.2.26: Spectrum Analyzer
Peak Cog
Summary of Contents for GV5
Page 2: ......
Page 4: ......
Page 8: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL PAGE 3 VIII VERSION 0 2 2014 07 23...
Page 16: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 3 1 8 VERSION 0 2 2014 07 23...
Page 18: ...VERSION 0 2 2014 07 23 PAGE 3 1 10 LJXUH 9 9 XGLR 3DWK ORFN LDJUDP...
Page 239: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL ROUTINE MAINTENANCE PAGE 3 3 10 VERSION 0 2 2014 07 23...
Page 249: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL LIST OF TERMS PAGE 3 5 2 VERSION 0 2 2014 07 23...
Page 250: ......