Replacing the Controller Module’s Battery
Replace the battery on the controller module’s controller PWB (A4A2) once a year, or whenever the
Controller - Low Battery
alarm appears (on the AUI, controller UI or via remote digital output).
Chemical leakage from an old battery can cause damage.
Interval
Every 12 months.
Parts and Tools
Replacement battery: 3 V lithium coin cell, 20 mm (Nautel Part # BBLT01, Panasonic # CR2032).
Procedure
Perform the following steps to replace the battery:
1.
Remove the upper, rear filter panel by loosening the 12 quarter-turn fasteners securing the panel to
the transmitter.
2.
Replace the battery in the
3V BATTERY
holder on the rear of the controller assembly (see
).
3.
Re-install the upper, rear filter panel removed in
.
4.
Check for any alarms on the AUI (local or remote) or controller UI (see
). Battery related alarms should clear.
5.
Reset the system clock via the AUI (local or remote) or controller UI (see
NOTE
: If the NTP server feature has been enabled, your clock setting will automatically reset within
approximately five minutes. See
“Configuring NTP Servers” on page 3.2.154
for more information.
Summary of Contents for GV5
Page 2: ......
Page 4: ......
Page 8: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL PAGE 3 VIII VERSION 0 2 2014 07 23...
Page 16: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 3 1 8 VERSION 0 2 2014 07 23...
Page 18: ...VERSION 0 2 2014 07 23 PAGE 3 1 10 LJXUH 9 9 XGLR 3DWK ORFN LDJUDP...
Page 239: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL ROUTINE MAINTENANCE PAGE 3 3 10 VERSION 0 2 2014 07 23...
Page 249: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL LIST OF TERMS PAGE 3 5 2 VERSION 0 2 2014 07 23...
Page 250: ......