GV10/GV7.5 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
PAGE 4.1.56
VERSION 3.2 2016-03-10
Figure 4.1.19: Fan Tray Assembly
4.
Remove the fan tray from the transmitter.
5.
Disconnect the suspect fan’s mating plug (B1P1 through B3P1).
6.
From the bottom of the fan tray, remove and retain the cooling fan’s two M3 screws that secure
the fan to the fan tray. See
7.
Obtain a replacement fan (Nautel Part # ZAP50) from the site spares kit, if purchased or a suitable
equivalent (vendor part # is Minebea Motor Mfg. Corp. 3115RL-07W-B79-E51).
8.
Install the replacement fan using retained screws.
9.
Reinstall the fan tray and secure using M4 screw. Reconnect D-sub connector W5P2.
Access fan removal hardware
(two M3 screws) from bottom
of fan tray.
NOTE:
Fan B1 is 5 kW Reject Fan 1
Fan B2 is 5 kW Reject Fan 2
Fan B3 is 10 kW Reject Fan 1