GV10/GV7.5 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
VERSION 3.2 2016-03-10
PAGE 4.1.51
1.
Use the transmitter’s AUI (local or remote) or controller UI alarm status/logs to isolate the defective
low voltage power supply (LVPS), noting there may be redundant (dual) supplies installed
or Power
Supply module.
2.
Open the transmitter front door and locate the suspect
LVPS / Power Supply module
. See
.
3.
as a guide, remove the
LVPS / Power Supply module
from the
front of the transmitter.
4.
Locate or obtain a replacement
LVPS / Power Supply module
(Nautel Part # UG92B).
5.
as a guide, reinstall the new
LVPS / Power Supply module
.
Figure 4.1.16: Removing/Installing LVPS
/ Power Supply
Modules
AC OK
and
DC OK
LEDs should be on (green)
after successful power supply installation.
If the associated RF power module is disabled,
the
DC OK
LED will not turn on until the module
is enabled.
Summary of Contents for GV10
Page 2: ......
Page 4: ......
Page 8: ...GV10 GV7 5 TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 3 2 2016 03 10...
Page 84: ...GV10 GV7 5 TROUBLESHOOTING MANUAL RESPONDING TO ALARMS PAGE 4 1 76 VERSION 3 2 2016 03 10...
Page 236: ......
Page 292: ...VERSION 3 2 2016 03 10 SD 36 Figure SD 36 NAFP109B Output Power Probe and Sample PWBs...
Page 296: ...VERSION 3 2 2016 03 10 SD 40...
Page 300: ...GV10 GV7 5 TROUBLESHOOTING MANUAL MECHANICAL DRAWINGS PAGE 4 5 4 VERSION 3 2 2016 03 10...
Page 313: ...VERSION 3 2 2016 03 10 MD 13 Figure MD 13 NAPA31C Power Amplifier PWB Q1...
Page 324: ...GV10 GV7 5 TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 3 2 2016 03 10...
Page 325: ......