Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1
Cleaning on Stop
– set the work time for the main (
Fan
) and the additional (
Cleaner
) air fan for the
cleaning cycle after extinction. These settings also apply for the intermediate automatic cleanings.
Cleaning after extinction caused by Back Burning alarm –
Cleaning on BB
– sets the work time
for the main (
Fan
) and the additional (
Cleaner
) air fan for the cleaning cycle if a back burning alarm
has been registered.
General Setup
-
- set the number of ignition attempts (
Retries
), the work time of the auger for
initial feed (
Feed
) and the speed of the Exhaust Fan (
EFan
).
Ignition cycle setup -
Cycle Setup
– adjust the work time of the heater before the fan turns on
and the following two work modes of the fan, which include speed and duration.
User Manual / version 2.6
http://www.naturela-bg.com/en/
page 17 of 28
The heater works for 30 sec.
before the fan turns on
After that, along with the
heater, the fan works for 2
min. on 5% of its power
Next 3 min., along with the
heater, the fan works on