6. INSTALLATION / SET-UP

WARNING: FAILURE TO FOLLOW THESE INSTRUCTIONS CAN DAMAGE THE UNIT. 
WARNING: SHOCK HAZARD 

If the input plug is connected and utility power is present, the outlets will be energized.

 

The front panel ON/OFF button will not 

turn these outlets off. 

Before beginning your Installation, please consider the following: 

The base unit should be used or stored in an indoor area with environmental temperature between 32° to 104°F (0° to 40°C) 
where it is close to an AC wall outlet for easily accessibility.

 

Please make sure the power cord will be plugged into a grounded AC 

wall outlet for safety, the power cord is 6 feet long or less.

 

Please keep the base unit away from direct sunlight, heat, 

moisture or conductive contaminants.    The solar panel should be placed outdoors where the best access to sunlight occurs. 

When placing the unit, allow a minimum of three inches of space around the unit for optimal ventilation. 

CHARGE THE BATTERY IMMEDIATELY UPON PURCHASING THIS PRODUCT. 

To ensure optimum battery run time and life expectancy, leave the 

unit

 continuously plugged into utility AC power and/or leave

solar panel plugged into the unit to keep the battery charged. 

MAIN  UNIT  INSTALLATION 

To install the unit, plug one end of the AC input power cord to the main unit and the other end directly into a wall outlet and unit 
is ready to use. 

Follow instructions below to test the unit: 

(If you have an extra battery Pod/s attach it/them to the main 

unit before you start the conditioning process.)

The unit will be automatically turned on when the AC power cord is plugged into the wall outlet. The 

Utility/Backup/Fault LED

 

and 

LED Display

 light turn on indicating the 

unit

 is ON.  The unit is functioning in standby mode and is ready to provide backup

power. AC output is now being provided directly from utility power. 

The Digital Read out should flash CHG- this indicates the unit is charging.

 

Now leave the unit charging for three days.

 

At 

some 

point the digital display will stop flashing CHG and will indicate “FUL”.  Ignore this indication and just leave the uni

t plugged in for 

the three day period. 

At the end of the Three days unplug the generator from the outlet and connect a load to the generator. 100-300 watts.    Let the 
generator power the load until it shuts itself off or begins to beep. NOTE:  when you unplug the unit from the wall outlet it 
automatically switches to battery mode. 

Now remove the load and recharg

e the Battery from the AC outlet until the display reads “FUL” Next run the batteries down 

again until the unit shuts itself off or begins to beep. 

Do this 3-5 times.  (You only need to leave the unit plugged in for 3 days one time, after that it is ready once the unit reads 

“FUL”)

 

Now the unit is successfully installed, functioning properly and ready for normal use. 

PV  SOLAR  PANEL  INSTALLATION 

WARNING: SHOCK, FIRE AND ENERGY HAZARDS.

   

Make sure the solar panel is covered with an opaque sheet or facing the ground before connecting or disconnecting the solar 
panel cable to the base unit.  All wiring must be done in accordance with applicable electrical wiring codes. 

CONNECTING THE BASE UNIT TO SOLAR PANEL: 

WARNING: SHOCK, FIRE AND ENERGY HAZARDS.

   

The Solar input port is rated at 20V 8A and is designed to be used with the solar panel. be sure the solar panel is designed for a 
12V  battery  system  and  with  a  maximum  open  circuit  voltage  more  than  13VDC  and  less  than  25VDC.

 

Please  refer  to  the 

specifications label on the solar panel before connecting.  Do not connect a PV source capable of delivering more than 8 amps.  
Connecting  a  solar  panel  with  a  higher  voltage  or  current  rating  will  permanently  damage  the  unit  and  may  cause  fire  and 
energy hazard. 

CAUTION: REVERSE POLARITY.

 

Improper connections (reversing the wire connection on the solar panel connection box) will cause the unit to malfunction and 
may permanently damage the unit. Damage caused by a reverse polarity connection is not covered by the warranty. 

z

Plug in the solar panel cord plug to the solar input port located at the back of the 

unit

.  Please note the polarity of the

connector. 

(Don’t force the connector; it will only go in one way.    It will ‘click’ into place)

z

Remove the opaque sheet or flip the solar panel up with the solar cell surfaces facing upwards. Adjust the mounting frame

of the solar panel to have the solar cell surface angled for the proper season and point the panel due south. When sunlight

is available, the solar charge indicator should automatically turn on and the “

Solar Power

 LED should either flash or remain

on solid depending on the battery status. 

NOTE: 

It is recommended to always charge the internal battery to a 100% state-of-charge, as shown by a steady green on the 

Solar Power

 LED. (The LED flashes while the solar panel is charging the battery.) 

Summary of Contents for Solar Generator 1800

Page 1: ...Solar Generator 1800 USER MANUAL ENJOY THE FREEDOM OF USING SOLAR POWER ...

Page 2: ...s have someone nearby in case of an emergency z Wear eye protection and gloves when working with batteries z Avoid touching your eyes while using this unit z Keepfreshwaterand soaponhandintheeventbatteryacidcomesincontactwith eyes If thisoccurs cleanserightaway with soap and water for a minimum of 15 minutes and seek medical attention z Batteries may produce explosive gases DO NOT smoke or have an...

Page 3: ... 5 Product Features 4 6 Installation Set up 5 7 Installing Additional Battery Pods 8 Operation 9 Operating the PV Solar Input 10 Understanding the Error Codes 11 Estimate Run Times 12 Battery Replacement 13 Troubleshooting 14 Specifications 15 Options for Expansion Accessories 16 Understanding Solar Electric Power 1 1 11 1 13 ...

Page 4: ... certain products and loads which require more current than the unit can provide It has a peak power output of 1800 watts maximum and a continuous load output wattage of 1440 watts when supplying backup power from its batteries This limit applies to the total of all items plugged into the product This output wattage is not sufficient to run products designed to produce large amounts of heat includ...

Page 5: ...two in the rear for powering electric devices that draw a maximum total of 1800 watts 1440 watts continuous All outlets are surge protected and backed up by the internal battery 19 7 Battery Level LED displays battery level in five stages 20 8 One 12V Cigarette Lighter Outlet for powering DC devices 21 9 Two USB Outlets for powering charging 5VDC digital devices e g cell phone pad camera etc Solar...

Page 6: ...ff or begins to beep NOTE when you unplug the unit from the wall outlet it automatically switches to battery mode Now remove the load and recharge the Battery from the AC outlet until the display reads FUL Next run the batteries down again until the unit shuts itself off or begins to beep Do this 3 5 times You only need to leave the unit plugged in for 3 days one time after that it is ready once t...

Page 7: ...h the solar cells facing down on a flat surface to minimize the output voltage to zero volts z Verify the Solar charge indicator is off z Disconnect the solar cable connector from the solar input port of the unit Gently squeeze the locking tabs on the sides of the plug while pulling it out to release the plug ...

Page 8: ... Improper connections reversing the wire connection on the wind generator connection will cause the unit to malfunction and may permanently damage the unit Damage caused by a reverse polarity connection is not covered by the warranty z Plug in the wind generator cord plug to the wind generator input port located at the back of the unit Please note the polarity of the connector Don t force the conn...

Page 9: ...applicable OVER VOLTAGE PROTECTION Utility Backup Power Fault LED stays RED Screen shows error code F_02 One beep per second Unit shuts down after 10 seconds Not applicable Unit starts recharging the internal battery when utility power is restored Turn on the unit to restore normal operation UNDER VOLTAGE SHUTDOWN During backup power operation the battery power has been completely exhausted No pow...

Page 10: ...art unit F_3 Inverter output has sensed overload or short circuit and was shutdown Check load connected to the output Reduce load and restart the unit F_4 Inverter has sensed internal temperature high and has shutdown Turn unit off and wait for 15 minutes before restarting Check if any object has blocked the air flow of the unit F_5 Inverter has sensed low voltage input and warning occurs Recharge...

Page 11: ...e utility for more than 24 hrs to fully charge the battery or leave the solar panel plugged into the battery pod for more than 72 hrs Battery is near the end of it s life Replace battery or battery pod s Solar Charger indicator is not ON when solar panel is connected Solar panel cannot supply sufficient power to start the solar charger and charge the battery Check location and direction of solar p...

Page 12: ...F 25 C Safety Conforms to UL STD 1778 CERTIFIED TO CSA STD C22 2 NO 107 3 05 Dimension 554 x 307 x 243mm FCC Class B according to FCC part15B and ANSI C63 4 2009 Weight 34 8kg INVERTER SPECIFICATION INTERNAL AC CHARGER SPECIFICATION Output Current Power 12A 1440W continuous 15A 1800W maximum Output Current 5 ADC Surge Power 2880W peak Output Voltage Absorption Float 14 8 13 5 VDC Output Voltage 12...

Page 13: ...ore returning the product After speaking to a customer service representative if products are deemed non working or malfunctioning a return materials authorization RMA will be issued The product may be returned to Nature ower for free replacement or repair within 90 days Products may not be returned without an RMA If the unit is repaired new or reconditioned replacement parts may be used at Nature...

Page 14: ...this case the batteries will eventually become drained even though the solar panels are trying to charge them In simpler terms the battery acts like a barrel of water with a spigot at the bottom The barrel can continue to supply water out of the spigot as long as water is being poured into the top of the barrel at least as fast as it is being drained out of the spigot But if the spigot is opened u...

Reviews: