Installation: 

  Choose an appropriate mounting location.  

  For indoor use, the unit can be mounted in any direction except with the DC Input panel facing 

downwards. 

  Use the mounting template below to mark the positions of the mounting screws. 

  Drill the 4 mounting holes and place the Inverter-Charger in position and fasten the unit to the 

mounting surface. 

 

 

 

 

Chassis Grounding Connection: 

DANGER:

 The unit chassis has to be grounded properly. Never operate the Inverter-

Charger without proper grounding. Failure to do so will result in death or serious injury. 

  Connect the grounding 

cable’s ring terminal to the unit ground screw. 

  Connect the other side of the cable to the common grounding point. 

 
DC Input Connection: 

CAUTION

: Reversing the DC Input terminal will damage the unit and it cannot be repaired. 

Damage caused by reverse polarity connection is not covered by the warranty.  

  Connect one end of the negative DC input cable to the Inverter-Charger DC negative terminal. 

Connect the other end of the negative DC input cable to the battery negative terminal. 

  Make sure the Disconnect Switch is in the OFF position. 

  Connect one end of the positive DC input cable to the Power Inverter DC positive terminal. 

Connect the other end of the positive DC input cable to one of the terminals of the Disconnect 
Switch. 

  Connect a DC input cable between the other terminal of the Disconnect Switch and one side of 

the terminal of the fuse holder. 

  Connect a DC input cable between the other terminal of the fuse holder and the battery positive 

terminal. 

  Install the selected fuse to the fuse holder. 

  Turn Disconnect Switch to ON position. 

 
AC Input Connections: 

Warning: 

Please

 

double check on the location of the AC input port located inside the 

wiring compartment. Misconnecting to the AC output port inside the same compartment 
will blow the unit and may catch fire. Before making any AC Input and output connection, 
please be sure the AC Input Source is not energized and the DC disconnect switch is OFF.

 

Important:

 A 30A branch breaker (not provided) is required to connect between the AC source 

and the Inverter-Charger.  

  Remove AC compartment cover by unscrewing the two screws located at the front of the AC 

compartment cover. 

  Connect the AC Input 

‘L’ wire between the unit’s AC Input port and the branch breaker terminal. 

  Connect the AC Input 

‘N’ wire between the unit’s AC Input port and the AC source ‘N’ terminal. 

 
 

Summary of Contents for 38326

Page 1: ...Version 1 1 1 Inverter 2000W with 55Amp Inverter Charger 38326 Owner s Manual ...

Page 2: ...een taken to ensure the accuracy of the contents of this guide Nature Power assumes no responsibility for errors or omissions Note as well that specifications and product functionality may change without notice Important Please be sure to read and save the entire manual before using your Nature Power Inverter Charger Misuse may result in damage to the unit and or cause harm or serious injury Read ...

Page 3: ...Page 3 Table of Contents 1 INTRODUCTION 4 2 PRODUCT DESCRIPTION 5 3 INSTALLATION 5 4 UNIT OPERATION 9 5 TROUBLESHOOTING 11 6 SPECIFICATIONS 14 7 WARRANTY 15 ...

Page 4: ...occurs cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention Batteries produce explosive gases DO NOT smoke or have an open spark or fire near the system Keep unit away from moist or damp areas Avoid dropping any metal tool or object on the battery Doing so could create a spark or short circuit which goes through the battery or another electrical tool that m...

Page 5: ...al safety wiring regulations and installation codes Failure to follow these instructions can damage the unit and could also result in personal injury or loss of life CAUTION Before beginning unit installation please consider the following The unit should be used or stored in an indoor area away from direct sunlight heat moisture or conductive contaminants When placing the unit allow a minimum of t...

Page 6: ...nding Cable Use of low resistance wire is required for all the DC connections between the unit and the battery bank For 32326 use minimum 2 0 AWG wire with maximum cable length of 5 feet Important The unit is grounded through the ground stud of the unit located near the DC Input terminal For the grounding cable connected between the unit s chassis and the earth ground use a matching cable size as ...

Page 7: ...the OFF position Connect one end of the positive DC input cable to the Power Inverter DC positive terminal Connect the other end of the positive DC input cable to one of the terminals of the Disconnect Switch Connect a DC input cable between the other terminal of the Disconnect Switch and one side of the terminal of the fuse holder Connect a DC input cable between the other terminal of the fuse ho...

Page 8: ...is limited to 16 6A for 2000W model 32326 Remote Display Connection The Remote Display on the unit is detachable To install the remote to different location an optional 6 pin standard RJ12 cable not provided is required Remove the 2 screws at the front of the Display Panel and remove the small RJ12 cable Install the optional RJ12 standard cable to your desired location Please note polarity Connect...

Page 9: ... Display LED Display Function Status Green solid Green Ful By Pass Mode Battery is fully charged Green flashing OFF bul By Pass Mode Battery charging in progress and is in BULK mode OFF abs By Pass Mode Battery charging in progress and is in ABSORPTION mode Amber solid Green 12 5 Battery Mode inverter is running display shows battery voltage in DC volts Amber 0 80 Battery Mode inverter is running ...

Page 10: ... high Check battery setting E11 Battery bad Battery did not accept charge E12 Internal transfer switch temperature is high and shutdown occurs Reduce load and check if any ventilation of the unit is blocked AC Load on Inverter Although the Power Inverter can provide high surge power up to two times the rated output power some high surge loads like sump pumps heavy duty motors etc may still trigger...

Page 11: ...5A 4A 55A 6A Battery Type and Voltage Setting Bulk Absorption Float FLo Flooded 14 4V 14 4V 13 5V GEL GEL 14 2V 14 2V 13 8V AG AGM 14 3V 14 3V 13 4V Fi Fixed 13 5 Vdc fixed voltage Battery Under Voltage Setting SdL Battery under voltage setting is set to LOW setting used for normal operation Under voltage alarm 11 0 Vdc Under voltage alarm recovery 11 3 Vdc Under voltage shutdown 10 5 Vdc Under vo...

Page 12: ...ger current reduced to 5A 85 C 185 F Charger current recover back to set value Environment Temperature 60 C 140 F Charger current reduced to 5A 55 C 131 F Charger current recover back to set value Enter Function Menu for unit setting To enter unit Function Menu press and hold Power and Select button together for about 5 seconds until a beep is sounded When you are in Function Menu Press Power butt...

Page 13: ...Page 13 ...

Page 14: ...ns are subject to change without notices Specification 38326 Inverter AC Output Power 2000W AC Output Current 16 6A AC Surge Power Peak 4000W AC Output Voltage Frequency 120 VAC 60 Hz AC Output Waveform Sinewave 3 THD Nominal DC Input Voltage 12 5 VDC No Load battery draw 1 5 ADC DC Input Voltage operating range 10 5 15 5 VDC Under Voltage Alarm 11 0 12 1 VDC Under Voltage Alarm Recovery 11 3 12 3...

Page 15: ... not apply to damage to units from misuse or incorrect installation connection Misuse includes wiring or connecting to improper polarity power sources If you are experiencing any problems with your unit please contact our customer service department at info naturepowerproducts com or Phone 1 800 588 0590 before returning product to retail store After speaking to a customer service representative i...

Reviews: