You are advised to change the water frequently in the tank and clean the diffuser once or twice a
week, particularly if you want to change the fragrance to be diffused.
In case of breakdown or breakage, spare parts are available! Contact your nearest
Nature & Découvertes store or check the list online on Nature & Découvertes website.
• Model: NA-377
• Input power supply : AC 100-240V, 50/60Hz
• Output power supply : DC24V 500mA
• Ceramic disc lifespan: +/- 3000 hours
• Tank capacity: 85ml
• Dimensions (approx) : Ø 10 cm x H 16.5 cm
• Recommended for a surface of: 30 m²
MAINTENANCE
TROUBLESHOOTING
1. Turn the appliance off and unplug it.
2. Remove the covers and empty the water on the opposite side of the air outlet. Do not empty the
water in the air outlet, this would damage the diffuser.
3. Clean the diffuser water tank using a soft damp cloth. If needed, use a little white vinegar strongly
diluted. Do not use corrosive detergents. Carefully rub the ceramic disc with a cotton bud being
careful not to scratch it.
Status
Causes
Solutions
Startup Failure/
Early Shutdown
Insufficient water
Fill water to the maximum water level indicator.
Improper power wire connection
Unplug the power adapter plug and reset
carefully.
Failure or
Abnormality of
Misting
Misting failure but normal light
The air inlet may be blocked. Check to make
sure there is nothing blocking the inlet and that
the device is placed on a flat / hard surface.
No misting after top cover is replaced Check the fan, if it is abnormal, please contact
Nature & Decouvertes
Oil contamination on mist plate
Clean the mist plate as mentioned in the
maintenance section of the manual.
Water
Leakage
Top cover off-centered
Replacing or adjusting the top cover may
resolve the problem.
High humidity or temperature too
low /too high in the room.
Adjust the room temperature or humidity.
HOW TO REPAIR YOUR DIFFUSER
TECHNICAL SPECIFICATIONS
This manual is also available from the after-sales service of your retailer.