Bit field
Name
Description
2
RXFUIM
Receive FIFO Underflow Interrupt Mask.
0: Mask
1: Not mask
1
TXFOIM
Transmit FIFO Overflow Interrupt Mask.
0: Mask
1: Not mask
0
TXFEIM
Transmit FIFO Empty Interrupt Mask.
0: Mask
1: Not mask
24.6.14
QSPI Interrupt Status Register (QSPI_ISTS)
Address offset: 0x30
Reset value: 0x0000 0000
Bit field
Name
Description
31:7
Reserved
Reserved, the reset value must be maintained
6
XRXOIS
XIP Receive FIFO Overflow Interrupt Status.
0: Invalid, after masking.
1: Validafter, after masking.
5
MMCIS
Multi-Master Contention Interrupt Status.
0: Invalid, after masking.
1: Valid, after masking.
4
RXFFIS
Receive FIFO Full Interrupt Status.
0: Invalid, after masking.
1: Valid, after masking.
3
RXFOIS
Receive FIFO Overflow Interrupt Status.
0: Invalid, after masking.
1: Valid, after masking.
2
RXFUIS
Receive FIFO Underflow Interrupt Status.
0: Invalid, after masking.
1: Valid, after masking.
1
TXFOIS
Transmit FIFO Overflow Interrupt Status.
0: Invalid, after masking.
1: Valid, after masking.
0
TXFEIS
Transmit FIFO Empty Interrupt Status.