3. Inverter Power Supply (U)
1. Discharge high voltage capacitors.
2. Remove 2 screws holding magnetron bracket. (Remove grounding
wire)
3. Remove 3 screws holding inverter and fan motor assembly.
4. Unplug 3 connectors of inverter PCB.
5. Remove 2 screws holding inverter PCB on to bracket.
NOTE: Do not pull by lead wires but make sure to pull housing
unless PCB or lead wire may break.
08-154M
08-153M
GROUND
METAL
RELEASE TAB
TO MAKE FALT
GROUND METAL
RELEASE TAB
TO MAKE FALT
08-149M
GROUND WIRE
GROUND METAL
08-181M