<TROUBLE>
<CHECK.>
<REMEDY>
Noise is too loud.
→
Check if there any deformation with the outer foil.
NO
Replace the outer foil or
Amplitude is too large.
→
→
→
→
oiling a drop for the foil.
↓↓↓↓
OK
<CHECK DRIVING BARS.>
NO
Replace the trimmer
Check if there is any deformation with trimmer driving bar and slit blade
→
→
→
→
driving bar or slit
driving bar.
blade driving bar.
↓↓↓↓
OK
<CHECK DRIVING HEAD AMPLITUDE.>
NO
Replace linear motor and
Turn the switch ON, and measure the amplitude using a pin of driving head.
→
→
→
→
module assembly.
(See the figure shown below.)
↓↓↓↓
OK
<CHECK TREMBLE LINEAR MOTOR.>
NO
Tighten the screw.
Confirm a screw if it is tightened firmly after replacing the back panel.
→
→
→
→
↓↓↓↓
OK
<CHECK TREMBLE LINEAR MOTOR.>
NO
Replace linear motor.
Check if there is any abnormal noise when putting the cardboard (ex. Individual
→
→
→
→
box) between the linear motor assembly and the front panel.
↓↓↓↓
OK
<CHECK TREMBLE LINEAR MOTOR.>
NO
Replace housing A.
Check the wear condition in each part, Housing A, Linear motor assembly or
→
→
→
→
Float guides.
↓↓↓↓
NO
Replace linear motor.
↓↓↓↓
OK
Replace float guides.
<TROUBLE>
<CHECK.>
<REMEDY>
Amplitude is too small.
→
<CHECK DRIVING HEAD AMPLITUDE.>
NO
Replace linear motor.
Does not sharp enough.
Turn the switch ON, and measure the amplitude using a pin of driving head.
→
→
→
→
↓↓↓↓
OK
(See the figure shown below.)
Replace module.