National CS-MK120AKH Operating Instructions Manual Download Page 9

8

DRY • COOL• FAN Operation

The air conditioner operates with the settings of your
choice.
From the next time on, the air conditioner will operate
with the same settings.

1

2

Press 

MODE

and select a mode.

Each pressing of the button advances the mode setting
in sequence.

Press 

OFF/ON

 .

Then OPERATION lamp
lights up.

 To  stop:

Press 

OFF/ON

 once again.

Then OPERATION lamp goes off.

FILTER

POWER

TIMER

OFF/ON

 To change the temperature setting:

 To change the air flow rate setting:

Press 

 to raise the temperature and press

 to lower the temperature.

Press 

FAN SPEED

.

 At smaller air flow rates, the cooling or heating effect is also

smaller.

 To change the air flow direction:

(See page 9.)

DRY or FAN mode

COOL  mode

The temperature
setting is not
variable.

C

Set to the temperature
you like.

DRY mode

COOL or FAN mode

Five levels of air flow rate setting from “

” to

” plus “

” are available.

Display

The air flow
rate setting
is not variable.

Display

POWERFUL Operation

POWERFUL operation quickly maximizes the cooling
effect in any operation mode. You can get the
maximum capacity with a touch of a button.

Pressing the (POWERFUL) button during operation starts
POWERFUL operation.

POWERFUL operation ends in 20 minutes.  Then the system
automatically operates again with the settings which were
used before POWERFUL operation.

Press 

POWERFUL

.

Displa

y

 To cancel POWERFUL operation:

Press 

POWERFUL

.

   

Notes on POWERFUL operation

In COOL mode

To maximize the cooling and heating effect, the capacity of
outdoor unit must be increased and the air flow rate be fixed
to the maximum setting.
The temperature and air flow settings are not variable.

In DRY mode

The temperature setting is lowered by 3°C and the air flow
rate is slightly increased.

In FAN mode

The air flow rate is fixed to the maximum setting.

1

Displa

y

MORE FEATURE

(Three step flow)

At the start heating, the human body feels uncomfortable if it
is directly exposed to the air flow even if it is warm. To
overcome this problem, the air conditioner is equipped with
a three step flow system to provide a comfortable warm air
around you.
1) At the start of operation, the flap is set toward the back.
2) When the air temperature has risen, the air starts

blowing downward to warm up the floor.

3) When the floor and walls are warmed up, the warm air

starts blowing toward the area around people.

NOTE

<Note on DRY mode operation>

This operation dehumidifies the indoor air when it is humid.

MORE FEATURE

(Precedence-room setting)

When setting the preference-room during installation, the
indoor unit’s operation mode always takes priority.
Please adjust the precedence-room setting to match your
life style. Moreover, for precedence-room settings, please
consult your dealer or service shop.

  

Notes on DRY mode operation

 This operation dehumidifies the indoor air when it is humid.

Summary of Contents for CS-MK120AKH

Page 1: ...ATING INSTRUCTIONS Outdoor Model CU 4MK260AKH Indoor Model CS MK90AKH CS MK120AKH CS MK180AKH Before using your air conditioner please read this operating instructions carefully and keep it for future...

Page 2: ...on 8 Adjusting the Air Flow Direction Adjusting the horizontal blade flap 9 Adjusting the louvre 9 Timer Operation OFF TIMER operation 10 ON TIMER operation 10 CARE Care and Cleaning Cleaning the air...

Page 3: ...in certain conditions Outdoor unit during cooling opera tion condensation may drip from the piping connections Do not place a vessel containing water on the unit Water may penetrate into the unit and...

Page 4: ...ing types of environments consult the shop Places with an oily ambient or where steam or soot occurs Salty environment such as coastal areas Places where sulfide gas occurs such as hot springs Places...

Page 5: ...e Receiver receives signals from the remote controller When the unit receives a signal you will hear a short beep Room temperature sensor senses the air temperature around the unit Indicator lamps TIM...

Page 6: ...it once again TEMPERATURE TIME adjustment buttons change the temperature or time setting CLOCK button See page 7 Preparation Before Operation Setting the Clock TIMER CANCEL button cancels the timer s...

Page 7: ...ever try to recharge the batteries 2 1 Operating the remote controller Choose a place from where the signals reach the unit Fix the holder to a wall a pillar etc with the screws supplied with the hold...

Page 8: ...Be careful not to cool the room too much Keeping the temperature setting at a moderate level helps save energy For cooling 26 C 28 C Cover windows with a blind or a curtain Blocking sunlight and air f...

Page 9: ...n Press POWERFUL Display To cancel POWERFUL operation Press POWERFUL Notes on POWERFUL operation In COOL mode To maximize the cooling and heating effect the capacity of outdoor unit must be increased...

Page 10: ...y swings up and down No display To stop the flap at an angle you like press SWING DRY COOL Unless SWING is selected you should set the flap at a near horizontal angle and at a near horizontal angle in...

Page 11: ...ir conditioner is not operating Press ON TIMER once again Press until the time setting reaches the point you like Every pressing of either button increases or decreases the time setting by ten minutes...

Page 12: ...onths old To order air purifying filters contact the service shop where you bought the air conditioner Once the air purifying filter element gets dirty it is not reusable but must be thrown away Opera...

Page 13: ...tion If no drain water is seen water may be leaking from the indoor unit Stop operation and consult the service shop if this is the case Before a long idle period 2 Clean the air filters and set them...

Page 14: ...om is cooled into mist by the cold air flow during cooling operation This happens when smells of the room furniture or cigarettes are absorbed into the unit and discharged with the air flow If this ha...

Page 15: ...there anything to block the air inlet or the outlet of the indoor and the outdoor units Is the temperature setting appropriate Are the windows and doors closed Are the air flow rate and the air direct...

Page 16: ...age breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning smell Water leaks from the indoor unit Turn the breaker OFF and call the service shop...

Page 17: ...16 MEMO...

Page 18: ...Printed in Thailand 3P069074 2A M00B080A 0102 HT Matsushita Electric Industrial Co Ltd Osaka 6542 8588 Japan...

Reviews: