FIG. 6: HUMIDISTAT-TIMER
Humidity Adjustment
To
INCREASE SET POINT
, turn the adjuster
clockwise
.
This makes the controller LESS sensitive.
To
REDUCE SET POINT
, turn the adjuster
anti-
clockwise
. This makes the controller MORE sensitive.
Speed selection (JP2)
.
The fan is factory set to low speed with jumper JP2 fitted.
To activate the high speed setting remove jumper JP2.
Timer Function (JP1)
JP1 to deactivate the timer, remove the jumper.
15min. timer = jumper in.
No timer = jumper out.
Comfort mode (On Pullcord)
To activate the comfort mode pull and hold the
pullcord for 5 Seconds. The LED will flash to
indicate that comfort mode has been set.
LED will flash
when Comfort
Mode is active
Pull and hold
For 5 Seconds
Humidity
Adjustment
JP1
JP2