16
| 5314 Blower
www.natvac.com | 800.253.5500
Preservation
Keep all intake, exhaust and ballast port coverings in place to prevent debris
or liquids from entering blower. Reapply rust preventative oil to all metal
parts, including the compression chamber every 6 months or more frequent-
ly if the relative humidity is greater than 80%.
While in storage, rotate the shaft three to four revolutions every two weeks
to keep gears coated in oil.
Before installing a blower that has been stored for any length of time, remove
the intake and exhaust covers and inspect the rotors and cylinders to insure
the absence of rust. In addition, remove the oil fill plug on drive oil tank and
inspect the gear for absence of rust.
·
Use a rust preventative oil with a flash point over 400
°
F
·
Dispose of used rust preventative oil according to local
regulations
INSTALLATION
Rotation and Airflow