18
http://www.national.com
A2.4 Clock Circuit Solder Jumper settings
Components can be installed or removed to select the path of the clock to the ADC.
While not as convenient as pin-type
jumpers, these introduce less distortion into the clock signal.
Termination A: Differential Sinusoid
Install C210, C216, and C217
Remove R223, R224, R225, and JP204
Termination B: Single Ended Sinusoid Install R222 and R223
Remove C210, C216, C217, R224, R225 and JP204
Termination C: Single Ended Square
Install R223, R224, R225, and JP204
Remove C210, C216, C217, and R222