Troubleshooting

In the event of unusual or undesired operation, consult the table below before contacting a 

service agent.

Problem

Possible Cause

Remedial Action

The fridge will not run

when connected to 12V,

but only when connected

to 230V mains.

12 Volt polarity reversed.

The battery is discharged.
The DC supply has inadequate 

wiring, causing voltage loss.

(See page 6 and 10)

Fridge is initially connected to a 

battery that is not fully charged.

Check polarity to battery is correct.

Recharge the battery.
Ensure all connections are secure.

Ensure supply has 4mm

2

 wire or 

thicker and that the vehicle’s body 

is not used as an earth.
Select “Low” on battery protection

(See page 10)

Fault ID light flashes once

every 4 seconds.

The ventilation fan is

noisy or not running

The ventilation fan is blocked or 

damaged.

There is excessive dust or dirt 

build-up on the fan

Check the ventilation fan for 

obstructions.

If the fan is broken, return the 

refrigerator to an authorised agent 

for repair.

The Fault ID light is 

flashing twice every 

4 seconds.

The Fault ID light is flashing 3 

times every 4 seconds.

The compressor failed to start 

correctly.

High pressure due to over-load 

or electronic failure.

Under high pressure conditions 

this fault will rectify itself automati-

cally when gas pressures equalise.

Continuous 3-flash conditions may 

require electronic control replace-

ment by an authorised service 

agent.

The Fault ID light is 

flashing 4 times every 

4 seconds.

The compressor is not main-

taining the correct 

minimum speed.

Continuous 4-flash conditions may 

require electronic control replace-

ment by an authorised service 

agent.

The Fault ID light is 

flashing 5 times every 

4 seconds.

Compressor area is 

over-heated.

The cooling fan is in-operative.

Ambient temperature very high.

Fridge over-loaded.

Check fan.

Ventilation inadequate.

Wait for ambient temperature to 

drop. (See page 11).

The thermostat display is

showing “ P r f “

The internal temperature probe 

is faulty, damaged or 

disconnected.

Contact a National Luna service 

agent for a probe replacement

Summary of Contents for Classic 40 litre

Page 1: ...PORTABLE REFRIGERATOR...

Page 2: ...re Relevant information common to all models Please complete the tear out return card to register your warranty National Luna fridges have been tested to international safety specifications SANS 60335...

Page 3: ...iring Guidelines 6 Temperature Settings 7 Celsius Fahrenheit Conversion Chart 8 Speed Control 9 Battery Protection 10 National Luna Classic Range 12 National Luna Double Door and Twin Range 15 Nationa...

Page 4: ...e refrigerator is used in an automotive application ensure that it is secured to prevent accidental movement The carry handles can be used with straps or tie downs if necessary A base mounting plate i...

Page 5: ...tting an in line fuse Although the fridge has a built in fuse it is recommended to install an additional fuse on the positive wire as close to the battery as possible This will protect against short c...

Page 6: ...ation system is incorrect wiring Most users do not understand the importance of maintaining battery voltage over the distance from the battery to the installed fridge While most car cigarette lighter...

Page 7: ...practical purposes National Luna has elected to place this temperature sensor on the metal surface forming the interior bin of the fridge freezer Thus the switching on and off of the compressor will b...

Page 8: ...ures can be selected between 20 C and 30 C in 1 C increments When powering up the fridge the first time the temperature inside the fridge will be reflected on the display NOTE the previously set tempe...

Page 9: ...speeds low 2 000 rpm medium 2 750 rpm and high 3 500 rpm On initial start up the fridge will automatically run at full speed to bring the inner bin temperature down as fast as possible It will then st...

Page 10: ...medium high selected setting Once the compressor has cut out it will not restart cut in until the voltage rises The table below reflects the set points BATTERY CAPACITY BATTERY VOLTAGE When using the...

Page 11: ...environments where the refrigerator is heavily loaded and temperature is very high 4 Minimum speed error The motor cannot maintain a minimum speed of 1900 rpm This can be the result of an internal ele...

Page 12: ...imum power consumption and high operating efficiency these single compartment fridges are recognised as the most powerful in the world Low power consumption is achieved using 60mm high density insulat...

Page 13: ...efault to ON automatically Note When the fridge is switched off the interior light will still function if the unit is connected to a power source Battery Protection The refrigerator is equipped with a...

Page 14: ...temperatures can be selected between 20 C and 30 C in 1 C increments When powering up the fridge the temperature inside the fridge will be reflected on the display NOTE the previously set temperature...

Page 15: ...having two fridges in one The Double Door range has two lids one for each compartment Double Door 74 95 Litre Twin Compartment 90 Litre Double Door Range 74 95 L 15 1 Lid 2 Interior light x 2 24V 5W 3...

Page 16: ...e freezer when the main lid is opened adding to the efficiency and ensuring stable temperatures within 1 Lid 2 Interior light 24V 5W 3 Lid locking latches 4 Cabinet exterior 5 Control panel 6 Carry ha...

Page 17: ...e When the fridge is switched off the interior light will still function if the unit is connected to a power source Battery Protection The user has the choice of three voltage levels at which the comp...

Page 18: ...cept the new setting and exit the setting mode 10 seconds after the last button was pressed The same procedure is used on both thermostat controls NOTE You can only set one thermostat at a time The du...

Page 19: ...anel 6 Carry handles 7 Compressor area 8 AC input with fuse 3 15A 9 DC input with fuse 15A 10 Fridge Bin 40 Lt Evaporator 11 Freezer bin 10 Lt with inner lid 12 Alternative lid handle position 13 Alte...

Page 20: ...C input with fuse 3 15A 9 DC input with fuse 15A 10 Cooling Bin Evaporator 11 Alternative lid handle position 12 Alternative lid latch position 13 Alternative lid hinge positions 4 5 11 10 13 12 6 7 8...

Page 21: ...he speed of the com pressor in order to conserve power and optimise performance For situations where maximum cooling power is required press and hold the Turbo button until the indicator is illuminate...

Page 22: ...capacity between the fridge and the freezer bin The thermostat control is placed on the fridge bin side and controls fridge temperature only The freezer has more cooling capability than the fridge com...

Page 23: ...aise or lower the desired temperature The thermostat will accept the new setting and exit the setting mode 10 seconds after the last button was pressed It will now remember the new set temperature The...

Page 24: ...he Low battery warning will sound when the voltage measured by the Weekender is below 10 5 volts It s recommended to re charge a battery that has been discharged to this level as soon as possible Comb...

Page 25: ...on the side of the refrigerator Keep the spare parts safe 3 Remove all three hinges from the rear of the refrigerator Also remove the hinge cover plates from the alternative hinge locations 4 Re fit t...

Page 26: ...oken return the refrigerator to an authorised agent for repair The Fault ID light is flashing twice every 4 seconds The Fault ID light is flashing 3 times every 4 seconds The compressor failed to star...

Page 27: ...ay be the cause of the malfunction of this product 6 National Luna shall not be responsible for any damages of any kind resulting from incorrect voltages or faults with regards to power supply which f...

Page 28: ...www nationalluna com National Luna South Africa Tel 27 0 11 452 5438 Fax 27 0 11 452 5263 NL 13 5 2011 M R...

Reviews: