![National Instruments WSN-3295 Installation Manual Download Page 11](http://html.mh-extra.com/html/national-instruments/wsn-3295/wsn-3295_installation-manual_709639011.webp)
©
National Instruments Corporation
11
NI WSN-3295 Outdoor IP Enclosure Installation Guide
Using the Second Ethernet Connection
If you want to use the second Ethernet connection and maintain your IP rating, you need to use the
no-crimp Ethernet plug included with the NI WSN-3295 to build an Ethernet cable for the second
connection. Complete the following steps to use the no-crimp Ethernet plug:
1.
Run your Ethernet cable through the glands into the NI WSN-3295.
Figure 9.
No-Crimp Ethernet Plug
2.
Attach the no-crimp Ethernet plug to your cable by lining the colored wires up with the chart on
the inside of the plug. Use the
A
chart for older CAT5 cables or the
B
chart for most new CAT5e
cables.
3.
Insert the wires into the tunnels, ensuring that they protrude all the way to the back of the plug.
4.
Finish by snapping the lid shut as shown in Figure 9.
Table 2.
IP Ratings
First Number (Protection Against Solid Objects)
Second Number (Protection Against Water)
0
No protection
0
No protection
1
Protects against objects greater than 50 mm
1
Protects against vertically dripping water
2
Protects against objects greater than 12.5 mm
2
Protects against direct sprays up to 15° from vertical
3
Protects against objects greater than 2.5 mm
3
Protects against direct sprays up to 60° from vertical
4
Protects against objects greater than 1 mm
4
Protects against direct sprays from all angles
5
Dust-protected (no harmful deposit)
5
Protects against low pressure water jets
6
Dust-tight
6
Protects against high pressure water jets
—
—
7
Immersible in water up to 1 m
—
—
8
Immersible in water beyond 1 m
1
Wire Connection
1