Appendix B
LED Indicators
B-2
www.ni.com
LEDs and System Startup Cycle
Table B-1 shows a system startup cycle and possible points of failure, up to
and including the state in which the
ONLINE
LED is asserted.
If either the
SYSF
or
FAIL
LED remains lit, perform the following steps:
1.
Power off the mainframe.
2.
Remove all other modules from the mainframe.
3.
Make sure that the VXIpc 870 Series switch and jumper settings are
correct.
4.
Make sure that the VXIpc 870 Series is seated properly in the
mainframe.
5.
Power on the mainframe and observe whether the
SYSF
and
FAIL
LEDs become unlit some time before the operating system boots.
Table B-1.
LEDs and System Startup Status
Step
LEDs Lit
Status
Possible Problem if
VXIpc 870 Fails
1
None
Machine just turned on.
The VXIpc 870 Series is not
receiving power or a fuse is blown.
2
PWROK
Machine just turned on.
The VXIpc 870 Series is now
starting to boot. All voltages are
present.
3
PWROK
,
FAIL
,
SYSF
Now asserting
FAIL
because
VXIbus interface has not been
initialized yet.
Power-on self configuration
(POSC) cannot execute because
of problems with system reset or
because the POSCEN switch is
incorrectly configured.
4
PWROK
POSC cycles are complete. VXI port
is ready to respond to Resource
Manager inquiries.
POSC completed successfully;
however, the Resource Manager
either hung or was not executed.
5
PWROK,
Online
Resource Manager has been
executed, indicating that the VXI
software can now communicate with
the VXIbus circuitry.
Resource Manager interface
initialized successfully.